Transportation And Storage; Technical Data - Husqvarna 555FX Operator's Manual

Hide thumbs Also See for 555FX:
Table of Contents

Advertisement

Available languages

Available languages

Check
Spark plug.
Fuel filter
The engine starts but stops again
Check
Fuel tank
Fuel filter
Carburetor
Air filter
Let the product cool before transportation or storage.
Remove the spark plug cap before long-term
storage.
Attach the product during transportation. Make sure
that it cannot move.
Make sure that there is no risk of fuel leaks, fuel
fumes, sparks or flames during transportation and
storage.

Technical data

Engine
Cylinder displacement, cu.in./cm
Idle speed, rpm
1346 - 004 - 03.06.2021
Possible cause
The spark plug is dirty or wet.
The spark plug electrode gap is in-
correct.
The spark plug is loose.
The fuel filter is clogged.
Possible cause
Incorrect fuel type.
The fuel filter is clogged.
The idle speed is not correctly adjus-
ted.
The air filter is clogged.

Transportation and storage

Technical data
555FX
3
3.25/53.3
2800
Procedure
Make sure that the spark plug is dry
and clean.
Clean the spark plug. Make sure that
the electrode gap is correct. Make
sure that the spark plug has a su-
pressor.
Refer to
for correct electrode gap.
Tighten the spark plug.
Replace the fuel filter.
Procedure
Empty the fuel tank and fill it with cor-
rect fuel.
Replace the fuel filter.
Adjust the idle speed with the idle
speed screw T.
Clean the air filter.
Attach the transport guard during transportation and
storage.
Clean and do servicing on the product before long-
term storage.
555FXT
555RXT
3.25/53.3
3.25/53.3
2800
2800
Technical data on page 31
555FRM
3.25/53.3
2800
31