  • Page 1 DOC-040-0700 Air Force One Installation Manual | REV 002 Page1...
  • Page 2 DOC-040-0700 Air Force One Installation Manual | REV 002 PREFACE This document covers the installation and basic function of the Air Force One® "True" Low Air Loss alternating pressure mattress. The mattress shown in this document features a standard 35" width mattress with a protective top cover. Mattresses should only be installed on the correct width beds for the given mattress width.
  • Page 3 DOC-040-0700 Air Force One Installation Manual | REV 002 Step 3. Locate the woven nylon straps along the sides, head, and foot sections of the mattress. Feed these straps around the bed frame and back up through the eyelets. Firmly snug the straps keeping the mattress tight to the frame. Step 4.
  • Page 4 DOC-040-0700 Air Force One Installation Manual | REV 002 Step 6. Affix the single remaining air hose to the metal fitting on the pump/blower assembly, until you hear a click. Step 7. Locate the power cord receptacle on the opposing side of the pump/blower assembly.
  • Page 5 DOC-040-0700 Air Force One Installation Manual | REV 002 ADJUSTING THE PRESSURE PUMP/BLOWER UNIT The Pressure Pump/Blower Assembly features multiple settings for patient care and comfort. ALTERNATING PRESSURE MODE One of the key features of the pump is the alternating pressure feature. This will cycle through the individual bladders based on the cycle time setting selected.
  • Page 6 DOC-040-0700 Air Force One Installation Manual | REV 002 AUTOFIRM AND FOWLER SETTINGS AUTOFIRM Autofirm is used to hyper inflate the mattress to assist with repositioning, transfers, or delivering care. Autofirm will time out after 15 minutes and return to previous pressure settings This can be selected by depressing the AUTOFIRM button on the control face;...
  • Page 7 DOC-040-0700 Air Force One Installation Manual | REV 002 PRESSURE LEVEL SETTINGS The level of overall air pressure in the mattress during any state of function can be adjusted using the LEVELS window on the face of the pump assembly. Using the + FIRM and - SOFT settings, you will actively raise and lower the LED count in the LEVELS window which corresponds directly to the amount of air pressure used in the mattress.