MasterCraft 312222 Owner's Manual
MasterCraft 312222 Owner's Manual

MasterCraft 312222 Owner's Manual

Shallow well jet pumps
Table of Contents

Advertisement

Available languages

Available languages

MD
312222 62-3525-6 1/2HP
312223 62-3526-4 3/4HP
312242 62-4003-2 1/2HP Tank Combo
I I n n s s t t a a l l l l a a t t i i o o n n / / O O p p e e r r a a t t i i o o n n / / P P a a r r t t s s
For further operating, installation,
or maintenance assistance:
C C a a l l l l 1 1 - - 8 8 7 7 7 7 - - 4 4 5 5 5 5 - - 5 5 5 5 0 0 8 8
OWNER'S MANUAL
Shallow Well Jet Pumps
4XXX 1203
CTC781 (9/15/06)

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 312222 and is the answer not in the manual?

Questions and answers

Summary of Contents for MasterCraft 312222

  • Page 1 OWNER’S MANUAL Shallow Well Jet Pumps 312222 62-3525-6 1/2HP 312223 62-3526-4 3/4HP 4XXX 1203 312242 62-4003-2 1/2HP Tank Combo I I n n s s t t a a l l l l a a t t i i o o n n / / O O p p e e r r a a t t i i o o n n / / P P a a r r t t s s...
  • Page 2 Safety READ AND FOLLOW E E L L E E C C T T R R I I C C A A L L S S A A F F E E T T Y Y SAFETY INSTRUCTIONS! C C a a p p a a c c i i t t o o r r v v o o l l t t a a g g e e m m a a y y b b e e h h a a z z a a r r d d o o u u s s . . To dis- charge motor capacitor, hold insulated handle screwdriver T T h h i i s s i i s s t t h h e e s s a a f f e e t t y y a a l l e e r r t t s s y y m m b b o o l l .
  • Page 3: Table Of Contents

    Tank System .......................12 Limited Warranty Mastercraft warrants that the products specified in this warranty are free from defects in material or workmanship. If within t t w w o o ( ( 2 2 ) ) y y e e a a r r s s from the date of the original consumer purchase, this pump shall prove to be defec- tive, it shall be repaired or replaced subject to the terms and conditions set forth below.
  • Page 4: Installation

    Installation REPLACING AN OLD PUMP To Household Pump Priming Water System Tee and Plug H H a a z z a a r r d d o o u u s s v v o o l l t t a a g g e e . . D D i i s s c c o o n n n n e e c c t t p p o o w w e e r r t t o o p p u u m m p p b b e e f f o o r r e e w w o o r r k k - - i i n n g g o o n n p p u u m m p p o o r r m m o o t t o o r r .
  • Page 5 Installation To Distribution Step 4. Install a priming tee, priming plug, and suction pipe to the pump System (see Figure 2). Connect the pipe from the well to the pump suction Pump Priming port, using the fewest possible fittings – especially elbows – as fit- Tee and Plug tings increase friction in the pipe (however, include a foot valve –...
  • Page 6 Discharge Pipe and Pressure Tank Connections PRE-CHARGED TANK CONNECTION (Figure 4) To Household Water System Step 1. Install two tees in the pump discharge port (see Figure 4). The pipe Priming Tee and size must be at least as large as the discharge port. Plug Step 2.
  • Page 7: Electrical

    Electrical D D i i s s c c o o n n n n e e c c t t p p o o w w e e r r b b e e f f o o r r e e w w o o r r k k i i n n g g o o n n p p u u m m p p , , m m o o t t o o r r , , p p r r e e s s s s u u r r e e s s w w i i t t c c h h , , o o r r w w i i r r i i n n g g . . M M O O T T O O R R S S W W I I T T C C H H S S E E T T T T I I N N G G S S N N O O T T E E : : 1/2 HP motors are wired for 115 volts only, and have no motor wiring to change.
  • Page 8 Electrical H H a a z z a a r r d d o o u u s s v v o o l l t t a a g g e e . . C C a a n n s s h h o o c c k k , , b b u u r r n n , , o o r r k k i i l l l l . . C C o o n n n n e e c c t t g g r r o o u u n n d d w w i i r r e e b b e e f f o o r r e e c c o o n n n n e e c c t t i i n n g g p p o o w w e e r r s s u u p p p p l l y y w w i i r r e e s s .
  • Page 9: Preparing To Start The Pump

    Preparing to Start the Pump PRIMING Never run pump against closed discharge. To do so can boil water inside pump, causing hazardous pressure in unit, risk of explosion and possibly scalding persons handling pump. Fill pump and piping Never run pump dry. Running pump without water may cause through pump to overheat, damaging seal and possibly causing burns to persons priming tee.
  • Page 10: Troubleshooting

    Troubleshooting S S Y Y M M P P T T O O M M P P O O S S S S I I B B L L E E C C A A U U S S E E ( ( S S ) ) C C O O R R R R E E C C T T I I V V E E A A C C T T I I O O N N Motor will not run Disconnect switch is off...
  • Page 11: Repair Parts

    Repair Parts 3 3 1 1 2 2 2 2 4 4 3 3 6 6 2 2 - - 3 3 5 5 2 2 5 5 - - 6 6 K K e e y y P P a a r r t t 3 3 1 1 2 2 2 2 2 2 2 2 6 6 2 2 - - 4 4 0 0 0 0 3 3 - - 2 2 3 3 1 1 2 2 2 2 2 2 3 3 6 6 2 2 - - 3 3 5 5 2 2 6 6 - - 4 4 N N o o .
  • Page 12: Tank System

    Tank System The tank is shipped pre-charged to 40 PSI. To Household Before starting the system, check precharge with an air pressure gauge. Isolation Valve Add or remove air to match the precharge pressure in the chart. Check precharge pressure periodically. If the pump seems to start too soon, it may need to have air added.
  • Page 13 NOTICE D’UTILISATION Pompes à éjecteur pour puits peu profonds 312222 62-3525-6 1/2HP 312223 62-3526-4 3/4HP 4XXX 1203 312242 62-4003-2 1/2HP Tank Combo I I n n s s t t a a l l l l a a t t i i o o n n / / F F o o n n c c t t i i o o n n n n e e m m e e n n t t / / P P i i è è c c e e s s Pour plus de renseignements concernant l’utilisation,...
  • Page 14 Sécurité LIRE TOUTES CES INSTRUCTIONS SÉCURITÉ CONCERNANT L'ÉLECTRICITÉ ET LES SUIVRE! AVERTISSEMENT L L a a t t e e n n s s i i o o n n d d u u c c o o n n d d e e n n s s a a t t e e u u r r p p e e u u t t ê ê t t r r e e d d a a n n - - g g e e r r e e u u s s e e .
  • Page 15 Système à réservoir......................12 Garantie limitée Mastercraft garantit que l’article spécifié au titre de la présente garantie est exempt de défauts de fabrication et de matériaux. Si la pompe fait défaut au cours d d e e s s d d e e u u x x ( ( 2 2 ) ) a a n n n n é é e e s s suivant la date d’achat, elle sera réparée ou remplacée conformément aux clauses et aux conditions indiquées ci-dessous.
  • Page 16: Installation

    Installation REMPLACEMENT D'UNE ANCIENNE POMPE To Household Bouchon et té Pump Priming Vers le système d'eau d’amorçcage Water System Tee and Plug de la maison AVERTISSEMENT Tension dangereuse. Couper l'arrivée de courant à la pompe de la pompe avant d'intervenir sur la pompe ou sur le moteur. 1 °...
  • Page 17 Installation Vers le système To Distribution 4 ° Poser le té d'amorçage, le bouchon d'amorçage et le tuyau d'aspiration sur d'eau de la System Bouchon et té la pompe (voir la Figure 2). Brancher le tuyau provenant du puits sur l'ori- maison d’amorçcage Pump Priming...
  • Page 18: Branchement De La Tuyauterie De Refoulement

    Branchement de la tuyauterie de refoulement et sur un réservoir sous pression BRANCHEMENT SUR UN RÉSERVOIR PRÉCHARGÉ Vers le système To Household d'eau de la maison Water System (Figure 4) Bouchon et tée Priming d’amorçage Tee and 1 ° Poser deux tés dans l'orifice de refoulement de la pompe (voir la Figure 4). de la pompe Plug Le diamètre du tuyau doit être au moins aussi grand que le diamètre de...
  • Page 19: Électricité

    Électricité D D é é b b r r a a n n c c h h e e r r l l e e c c o o u u r r a a n n t t é é l l e e c c t t r r i i q q u u e e a a v v a a n n t t d d ' ' i i n n t t e e r r v v e e n n i i r r s s u u r r l l a a p p o o m m p p e e , , l l e e m m o o t t e e u u r r , , l l e e m m a a n n o o s s t t a a t t o o u u l l e e c c â â b b l l a a g g e e . . R R É...
  • Page 20 Électricité AVERTISSEMENT T T e e n n s s i i o o n n d d a a n n g g e e r r e e u u s s e e . . R R i i s s q q u u e e d d e e s s e e c c o o u u s s s s e e s s é é l l e e c c t t r r i i q q u u e e s s , , d d e e b b r r û...
  • Page 21: Préparations Avant Le Démarrage De La Pompe

    Préparations avant le démarrage de la pompe AMORÇAGE AVERTISSEMENT Ne jamais faire fonctionner la pompe contre un refoulement fermé, sinon l'eau risque de bouillir à l'intérieur de la pompe, des pressions dangereuses peuvent s'accumuler à l'intérieur de la pompe, une explosion Remplir la pompe risque de s'ensuivre et les personnes qui manipulent la pompe pourront être Fill pump...
  • Page 22: Diagnostic Des Pannes

    Diagnostic des pannes S S Y Y M M P P T T ÔMES CAUSES PROBABLES REMÈDES Le moteur ne tourne Le sectionneur est ouvert. S'assurer que le sectionneur est enclenché. Le fusible est sauté ou le disjoncteur est Remplacer le fusible ou réenclencher le disjoncteur. déclenché.
  • Page 23: Pièces De Rechange

    Pièces de rechange 3 3 1 1 2 2 2 2 4 4 3 3 6 6 2 2 - - 3 3 5 5 2 2 5 5 - - 6 6 D D é é s s i i g g n n a a t t i i o o n n 3 3 1 1 2 2 2 2 2 2 2 2 6 6 2 2 - - 4 4 0 0 0 0 3 3 - - 2 2 3 3 1 1 2 2 2 2 2 2 3 3 6 6 2 2 - - 3 3 5 5 2 2 6 6 - - 4 4 R R é...
  • Page 24: Système À Réservoir

    Système à réservoir Le réservoir est expédié préchargé à 40 lb/po Vers l’habitation To Household Avant de démarrer le système, vérifier la précharge à l’aide d’un Isolation Valve Robinet d’isolement manomètre. Ajouter de l’air pour que la charge corresponde à la pression de précharge indiquée dans le tableau.

This manual is also suitable for:

31222331224262-3525-662-3526-462-4003-2

Table of Contents