TROUBLESHOOTING
ANOMALY DETECTED
POSSIBLE CAUSES
• The appliance does not
• Power failure
work and the main switch
• A thermal protection has
(IG) warning light does not
been temporarily triggered
turn up
• The machine does not
• The coolant circuit is le-
cool, the fan (M), the stirrer
aking or has an insufficient
(F) and the compressor (H)
operating pressure
do not work)
• The refrigerating unit is
• Stirrer motor overheating
working, but the stirrer (F)
• Stirrer motor breakdown
is stationary
or power drop
• The machine does not
• System overheating
cool (the fan (M), and the
• Lack or insufficient water
compressor
(H)
are
not
level in the tank
working but the stirrer (F) is
working
• The machine does not
• Power supply failure on
cool (the compressor (H) is
the compressor
not working but the fan (M)
• Compressor overheating
and the stirrer (F) are wor-
• Compressor breakdown
king
• The compressor runs con-
• Thermostat failure
tinuously and does not stop,
• Probe (G) failure
causing the beverages to
freeze
• The machine does not
• Power supply failure on
cool (the fan (M) is not wor-
the fan motor
king, but the compressor
• Fan motor failure
(H) and the stirrer (F) are
working)
• The stirrer (F) motor is
• Anomaly on bearings or
noisy
motor shaft supports
• Pump supports damaged
• The system is working re-
• Beverage
gularly but it is not possible
dirty or clogged
to tap beverages
CHECKS AND POSSIBLE
SOLUTIONS
• Check
that
the
power
cable is plugged into the
electric socket properly
• Check for disconnected
wires or cables; check the
electric system of the instal-
lation site
• Check
the
refrigerating
circuit pressure or any lea-
kage of coolant liquid; re-
store the correct operating
conditions
• Check the electric system
• Replace the stirrer
• Check the probe (E)
• Replace the probe
• Fill the tank
• Check the electric con-
nections and the electric sy-
stem of the appliance
• Replace the compressor
• Replace the faulty parts
• Contact Vinservice Custo-
mer Service.
• Check the electric con-
nections and the electric sy-
stem of the appliance
• Replace the fan motor
• Replace the stirrer motor
• Replace the pump
conduits
are
• Clean or replace the parts
concerned
MACHINE PARTS
A
B
C
D
WHEELS (OPTIONAL)
E
F
G
H
IG
L
C
TR
4
SIGNS
M
COOLING COILS
N
PUMP
O
DISTRIBUTOR
P
Q
TANK
R
STIRRER
PROBE
TE
ELECTRONIC THERMOSTAT
COMPRESSOR
TM
MECHANICAL THERMOSTAT
MAIN SWICH
TR
TRANSFORMER (OPTIONAL)
CONDENSER
F
R
B
Q
IG
TE
E
N
L
M
FAN
EXPANSION VALVE
EVAPORATOR
HANDLES
OVERFLOW
REMOVABLE PANEL
A
G
O
H
D
5