Summary of Contents for Kohler SDMO PERFORM 3000 XL TB UK C5
Page 1
Manuel d'utilisation et d’entretien (Notice originale) Instruction and maintenance manual (Translation of the original note) PERFORM 3000 XL TB UK C5 3000 XL TB UK C5 33522201001_1_1 11/2019...
Page 5
CONTENTS 1..Preface 6..Transporting and storing the generating set 2..Instructions and safety regulations (personal protection) 7..Repairing minor faults 3..Getting started with the generating set 8..Technical specifications 4..Using the generator set 9..Conditions of warranty 5..Generating set maintenance 1 Preface IMPORTANT Material damage Before use, read this manual and the safety instructions provided alongside it thoroughly.
Page 6
Risks relating to exhaust gases DANGER RISK OF POISONING DANGER OF DEATH (if appropriate) The carbon monoxide present in the exhaust gas may lead to death by inhalation if the concentration levels in the atmosphere are too high. Always use the unit in a well ventilated area where the gases cannot accumulate. For safety reasons and for correct operation of the unit, correct ventilation is essential (risk of poisoning, engine overheating and accidents involving, or damage to, the surrounding equipment and property).
Page 7
2.7.4 Connection and choice of cables For all connections, use flexible, strong rubber-sheathed cables which comply with standard IEC 60245-4 or equivalent cables, and ensure that these are kept in perfect condition. Only use one item of class I electrical equipment per socket and connect up equipment using a cable equipped with a PE protective conductor (green/yellow);...
Page 8
Initial commissioning On taking delivery and commissioning the unit: Check that it is complete and not damaged in any way. If the unit is fitted with a transport bracket, remove it. The transport bracket is a metal plate located underneath the engine, close to the earth terminal.
Page 9
Starting the generating set Once the daily checks have been performed, and having read the instructions and safety regulations carefully: If the outdoor temperature is above 0°C: If the outdoor temperature is below 0°C: Open the fuel tap (A5). 1. Open the fuel tap (A5) Check that the air filter is in the normal position for use 2.
Page 10
5.3.1 Drain the engine oil To ensure that the oil service is performed quickly and correctly, the oil must be changed when the engine is warm (start the unit and allow it to run for a few minutes if necessary). Place a suitable container under the oil drain screw (A12-B5), then remove the oil dipstick/filler plug (A2-B1) and the oil drain screw.
Page 11
6 Transporting and storing the generating set Transport and handling conditions The unit should be handled gently and sudden movements should be avoided. Ensure that the place where it is to be stored or used is carefully prepared beforehand. Before any fixed installation on a trailer or inside a vehicle, consult one of our approved agents.
Page 12
Power factor Serial numbers will be required when requesting troubleshooting advice or spare parts. For your records, please enter the unit and engine serial numbers below. Engine manufacturer:(e.g. Engine serial number: (e.g Kohler (SERIAL Unit serial number: Kohler) NO. 4001200908)) ……/…………..
Page 13
Serial numbers: description: PERFORM 3000 XL 09-2019-00000000-000 Generating set KOHLER-SDMO 3499231003572 TB UK C5 > 52-2026-99999999-999 1. Comply with the safety requirements set out in the Low Voltage Directive - 2014/35/EU of 26 February 2014 in application of the harmonized standard EN ISO 8528-13: 2016 2.
Page 14
CASES OF EXCLUSION FROM THE WARRANTY: Warranty exclusion applies in the following cases: damage resulting from transporting the unit; incorrect installation or installation not complying with SDMO Industries recommendations and/or technical and safety standards; use of non-recommended products, components, replacement parts, fuel or lubricants; incorrect use or misuse of the unit; modification or conversion of the unit or any of its components not authorized by SDMO Industries;...