Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
Note
For detailed dimensions of the device with either DIN rail or panel hardware installed,
refer to
2.3.1

Mounting the Device on a DIN Rail

For DIN rail installations, the RUGGEDCOM RMC41 can be ordered with a DIN rail
adapter preinstalled on the back of the chassis. Use the adapter to mount the device
to a standard 35 mm (1.4 in) IEC/EN 60715 or TS35 DIN rail.
Mounting the Device
To mount the device to a DIN rail, do the following:
1.
2.
3.
RUGGEDCOM RMC41
Installation Manual, 04/2021, C79000-G8976-1010-11
"Dimension Drawings (Page
Hook the top teeth of the adapter onto the DIN rail.
Note
The adapter features a sliding release with a slot at the bottom for a flathead
screwdriver.
1
DIN Rail
1
DIN Rail Adapter
2
Figure 2.1
Mounting the Device to a DIN Rail
Insert a flathead screwdriver into the slot of the sliding release and move it
down.
Push the device against the bottom of the DIN rail, then let go of the sliding
release to latch the device.
2.3.1 Mounting the Device on a DIN Rail
19)".
3
Installing the Device
1
1
2
2
7