Panametrics BWT System Installation Manual page 36

Table of Contents

Advertisement

Chapter 3. Acoustic Isolation Installation (FIPA Buffers)
3.
Turn the nut on the second stud 1/8 turn. The second stud should be diametrically opposite the first stud. Proceed
to tighten the remaining studs in the order shown below, or in a similar manner.
4.
Turn each nut an additional 1/8 turn. Be sure to TURN THE NUTS IN THE SEQUENCE SHOWN.
5.
Use Table 2 below to determine the appropriate final torque for your studs.
Flange Size
and Rating
1 1/2" ANSI 150#
1 1/2" ANSI 300#
1 1/2" ANSI 600#
1 1/2" ANSI 900#
1 1/2" ANSI 1500#
1 1/2" ANSI 150#
1 1/2" ANSI 300#
1 1/2" ANSI 600#
1 1/2" ANSI 900#
1 1/2" ANSI 1500#
28
Turn first nut 1/8 turn.
1
3
4
2
4-Hole Flange
Turn second nut 1/8 turn.
1
3
4
2
4-Hole Flange
Table 2:
Stud Rating with
4 Studs/Flange
316 Stainless Steel
B8M,C,1
B8M,C,1
B8M,C,1
B8M,C,1
B8M,C,1
carbon steel
B7
B7
B7
B7
B7
1
5
8
4
3
7
6
2
8-Hole Flange
1
5
8
4
3
7
6
2
8-Hole Flange
Stud Diameter (in.)
x Length (in.)
1/2" x 3 1/4"
3/4" x 4 3/4"
3/4" x 4 3/4"
1" x 6 "
1" x 6"
1/2" x 3 1/4"
3/4" x 4 3/4"
3/4" x 4 3/4"
1" x 6 "
1" x 6"
Torque in
ft-lb (N-m)
56 (76)
82 (111)
82 (111)
107 (145)
107 (145)
56 (76)
82 (111)
82 (111)
107 (145)
107 (145)