DVR4C | Installation Manual | Menu system
4.4 Recording >
The overall schedule consists of 4 periods: Weekday Day,
Weekday Night, Weekend Day and Weekend Night. The
start and end time of each period is set in the Profiles
menu. Recording conditions can be configured for each of
the four periods.
>> RECORDING
Set the normal recording rate and quality to be used for
all cameras.
Set the recording rate and quality that are used when an
input alarm is triggered. All cameras then record at these
values when an input alarm is triggered.
For each camera separately, set the conditions for

recording:

Always - camera is always recorded at the set
recording rate and quality.
Motion only - camera is recorded at the normal rate
and quality only when motion is detected (no images
are recorded when there is no motion).
Motion + auto snapshot - camera is recorded at the
normal rate and quality when motion is detected. The
rest of the time a snapshot of the camera picture is
recorded (I-frame images only).
Event Recording time can be configured to a maximum
of 120 seconds or to follow the event duration.
Pre-event recording time can be configured to a
maximum of 30 seconds. Pre-event recording takes
place:
a. on an alarm input if the normal recording rate is 0
IPS,
b. on a motion event (if a motion mode is selected).
Bosch Security Systems | Version 1. 1
4.5 Event Setup >
The sensitivity of the motion detection has three levels,
Low, Medium and High or set to Off for no detection.
To setup the motion detect area for the whole screen,
select Select All.
To clear the existing motion detect area setting, select
Clear All.
To edit the motion area, select Custom Area. A 16x12
grid is displayed on the monitor. With the scroll keys,
move around the grid. Press the play key to select a
specific area. A blue square indicates a selected area. To
unselect a selected area, move on to it and press the play
key. When area selection is completed, press ESC to
close the area selection mode. When motion is detected
in a selected square, it turns red.
Four different alarm inputs (Input 1, Input 2, Input 3,
Input 4) can be connected. Each alarm input can be
configured On (default) or Off. An activated input alarm
starts alarm recording on all cameras.