Casio IT-G500 Series Software Manual page 51

Hide thumbs Also See for IT-G500 Series:
Table of Contents

Advertisement

Validation count
Validation is carried out for a specified number of times to check if scanned data is valid, and then
the data is output only if it is valid. The number of validations can be set either on the Control
Panel or using the laser scanner library. The following settings are available, using a combination
of 2-value and 4-value codes (default setting: 1).
1
2-value code: 1 validation/ 4-value code: 0 validations, validation is possible
with only a one-sided scan
2
2-value code: 1 validation/ 4-value code: 1 validation, validation is possible
with only a one-sided scan
3
2-value code: 2 validations/ 4-value code: 2 validations, validation is
possible with only a one-sided scan
4
2-value code: 2 validations/ 4-value code: 3 validations, validation is
possible with only a one-sided scan
5~9
2-value code: 2 validations/ 4-value code: 3 validations, validation is
possible with right-left double-sided scan
Read count
In "Continuous Scanning" mode, scanning continues for the preset number of scanning times, and
then it will stop in standby state. The effective number can be set either on the Control Panel or
using the laser scanner library. The setting range is 1~9 times, and the default is 1 time.
Scanning period
The effective scan time after the trigger key is pressed can be set either on the Control Panel or
using the laser scanner library. After the preset time has elapsed, the scanner will go into standby
state automatically.
The setting range is 1~9s, and the default is 1s.
Double scanning prevention function
This prevents scanning the same bar code twice when the "Continuous Scanning" mode has been
set. Scanning the same bar code again will be prohibited until scanning stops and resumes.