Download Print this page
EVAPCO ATC-DC Series Rigging And Assembly Instructions

EVAPCO ATC-DC Series Rigging And Assembly Instructions

Closed circuit cooler

Advertisement

Quick Links

Assembly Instructions
eco-ATWB-H Closed Circuit Cooler
EVAPCO, Inc. — World Headquarters & Research/Development Center
P
HONE
EVAPCO North America
EVAPCO, Inc.
World Headquarters
P.O. Box 1300
Westminster, MD 21158 USA
Phone: 410-756-2600
Fax: 410-756-6450
E-mail: marketing@evapco.com
EVAPCO East
5151 Allendale Lane
Taneytown, MD 21787 USA
Phone: 410-756-2600
Fax: 410-756-6450
E-mail: marketing@evapco.com
EVAPCO Midwest
1723 York Road
Greenup, IL 62428 USA
Phone: 217-923-3431
Fax: 217-923-3300
E-mail: evapcomw@evapcomw.com
EVAPCO West
1900 West Almond Avenue
Madera, CA 93637 USA
Phone: 559-673-2207
Fax: 559-673-2378
E-mail: contact@evapcowest.com
EVAPCO Iowa
925 Quality Drive
Lake View, IA 51450 USA
Phone: 712-657-3223
Fax: 712-657-3226
EVAPCO Iowa
Sales & Engineering
215 1st Street, NE
P.O. Box 88
Medford, MN 55049 USA
Phone: 507-446-8005
Fax: 507-446-8239
E-mail: evapcomn@evapcomn.com
EVAPCO...S
Rigging and
ATC-DC Condenser
EVAPCO Products are Manufactured Wordwide
EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA
: 410-756-2600 • F
: 410-756-6450 • E-
AX
EVAPCO Northwest
5775 S.W. Jean Road, Suite 104
Lake Oswego, Oregon 97035 USA
Phone: 503-639-2137
Fax: 503-639-1800
EVAPCO Newton
701 East Jourdan Street
Newton, IL 62448 USA
Phone: 618-783-3433
Fax: 618-783-3499
E-mail: evapcomw@evapcomw.com
EVAPCO-BLCT Dry Cooling, Inc.
981 US Highway 22 West
Bridgewater, New Jersey 08807 USA
Phone: 1-908-379-2665
E-mail: info@evapco-blct.com
Refrigeration Valves &
Systems Corporation
A wholly owned subsidiary of EVAPCO, Inc.
1520 Crosswind Dr.
Bryan, TX 77808 USA
Phone: 979-778-0095
Fax: 979-778-0030
E-mail: rvs@rvscorp.com
EvapTech, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
8331 Nieman Road
Lenexa, KS 66214 USA
Phone: 913-322-5165
Fax: 913-322-5166
E-mail: marketing@evaptech.com
Tower Components, Inc.
A wholly owned subsidiary of EVAPCO, Inc.
5960 US HWY 64E
Ramseur, NC 27316
Phone: 336-824-2102
Fax: 336-824-2190
E-mail: mail@towercomponentsinc.com
Visit EVAPCO's Website at:
H
PECIALISTS IN
: marketing@evapco.com
MAIL
EVAPCO Europe
EVAPCO Europe BVBA
European Headquarters
Industrieterrein Oost 4010
3700 Tongeren, Belgium
Phone: (32) 12-395029
Fax: (32) 12-238527
E-mail: evapco.europe@evapco.be
EVAPCO Europe, S.r.l.
Via Ciro Menotti 10
I-20017 Passirana di Rho
Milan, Italy
Phone: (39) 02-939-9041
Fax: (39) 02-935-00840
E-mail: evapcoeurope@evapco.it
EVAPCO Europe, S.r.l.
Via Dosso 2
23020 Piateda Sondrio, Italy
EVAPCO Europe GmbH
Insterburger Straße 18
40670 Meerbusch, Germany
Phone: (49) 2159-69560
Fax: (49) 2159-695611
E-mail: info@evapco.de
Flex coil a/s
A wholly owned subsidiary of EVAPCO, Inc.
Knøsgårdvej 115
DK-9440 Aabybro Denmark
Phone: (45) 9824 4999
Fax: (45) 9824 4990
E-mail: info@flexcoil.dk
EVAPCO S.A. (Pty.) Ltd.
A licensed manufacturer of EVAPCO, Inc.
18 Quality Road
Isando 1600
Republic of South Africa
Phone: (27) 11-392-6630
Fax: (27) 11-392-6615
E-mail: evapco@evapco.co.za
Evap Egypt Engineering Industries Co.
A licensed manufacturer of EVAPCO, Inc.
5 El Nasr Road
Nasr City, Cairo, Egypt
Phone: 2 02 24022866 /2 02 24044997
Fax: 2 02 24044667/2 02 24044668
E-mail: Primacool@link.net / Shady@primacool.net
http://www.evapco.com
T
P
EAT
RANSFER
RODUCTS AND
Bulletin 124H
EVAPCO Asia/Pacific
EVAPCO Asia/Pacific Headquarters
1159 Luoning Rd. Baoshan Industrial Zone
Shanghai, P. R. China, Postal Code: 200949
Phone: (86) 21-6687-7786
Fax: (86) 21-6687-7008
E-mail: marketing@evapcochina.com
EVAPCO (Shanghai) Refrigeration
Equipment Co., Ltd.
1159 Luoning Rd., Baoshan Industrial Zone
Shanghai, P.R. China, Postal Code: 200949
Phone: (86) 21-6687-7786
Fax: (86) 21-6687-7008
E-mail: marketing@evapcochina.com
Beijing EVAPCO Refrigeration
Equipment Co., Ltd.
No. 66, District 4,
Yanqi Development Zone, Huairou,
Beijing 101407 P.R. China
Phone: (86) 10 6166-7238
Fax: (86) 10 6166-7395
E-mail: evapcobj@evapcochina.com
EVAPCO Australia (Pty.) Ltd.
34-42 Melbourne Road
P.O. Box 436
Riverstone, N.S.W. Australia 2765
Phone: (61) 2 9627-3322
Fax: (61) 2 9627-1715
E-mail: sales@evapco.com.au
EVAPCO Composites Sdn. Bhd
No. 70 (Lot 1289) Jalan Industri 2/3
Rawang Integrated Industrial Park
Rawang, Selangor, 48000 Malaysia
Phone: 60 3 6092-2209
Fax: 60 3 6092-2210
EvapTech Asia Pacific Sdn. Bhd
A wholly owned subsidiary of EvapTech, Inc.
B-6-1, IOI Boulevard
Jalan Kenari 5, Bandar Puchong Jaya
47170 Puchong, Selangor Darul Ehsan
Malaysia
Phone: (60-3) 8070-7255
Fax: (60-3) 8070-5731
E-mail: marketing-ap@evaptech.com
.
S
ERVICES

Advertisement

loading
Need help?

Need help?

Do you have a question about the ATC-DC Series and is the answer not in the manual?

Questions and answers

Summary of Contents for EVAPCO ATC-DC Series

  • Page 1 ATC-DC Condenser eco-ATWB-H Closed Circuit Cooler EVAPCO Products are Manufactured Wordwide EVAPCO, Inc. — World Headquarters & Research/Development Center EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA : 410-756-2600 • F : 410-756-6450 • E- : marketing@evapco.com...
  • Page 2 This includes piping, ductwork, conduit, and electrical connections. These items must be flexibly attached to the Evapco unit so as not to transmit additional loads to the equipment as a result of seismic or wind forces.
  • Page 3 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Rigging Basin Section Lifting devices are located in the upper corners of the basin section for lifting and final positioning purposes as shown in Figures 3 and 4. The hook of the crane must be a minimum dimension of “H”...
  • Page 4 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Joining Multi-Cell Units Basin Sections - 10’ & 12’ Wide Models (24’ to 40’ Long) 4. Rig the second basin section adjacent to the equalizer flume on the steel support as shown in Figure 6. 5.
  • Page 5 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Joining Multi-Cell Units Basin Sections - 17’ and 24’ Wide Models (12’ to 40’ Long) 4. Clean the mating flanges on the equalizer flume on the end to be field connected. Apply a layer of sealer tape on SEALER TAPE the flange, centered between the hole centers and the outside edge.
  • Page 6 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Coil/Fan Section Coil Section Four lifting ears are provided in the lower corners of most coil/fan sections for lifting into final position. 18ʼ, 20’ and 21’long sections will have two additional lifting ears in the middle of the section. Use all lifting ears. A spreader beam must be used for lifting the top section(s) as shown in Figures 12 and 13.
  • Page 7 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Fan/Coil Section Min. “H” Dimension 3-6 Feet 8 Feet 8.5 and 9 9 Feet 10.5 Feet 11 Feet 12 Feet 12 Feet 14 Feet 14 Feet 18 Feet 17 Feet 20 Feet 18 Feet 21 Feet 19 Feet Table 2 - Minimum “H”...
  • Page 8 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Assembly of the Coil Section to the Basin Section (3’, 4’, 8.5’, 10’ and 12’ Wide Models) Before assembling the coil section to the basin section, remove any loose parts shipped in the pan. Wipe the flanges on the bottom of the coil section.
  • Page 9 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Assembly of the Fan Section to the Coil/Basin Section (3’, 4’, 8.5’, 10’ and 12’ Wide Models) Before assembling the fan section to the coil/basin section, wipe the flanges on the bottom of the fan section. Check to see that the motor access doors are in the correct position relative to the basin section (see certified print).
  • Page 10 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Mounting Fan Screens 10’ & 12’ Wide by 12’ or 24’ Long Models 20’ & 24’ Wide by 12’ or 24’ Long Models 1/2” BOLTS FAN SCREEN ROD In certain situations some units may be shipped with the fan screens in the basin.
  • Page 11 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Assembly of Sloped Ladders When sloped ladders are supplied with a unit, they are shipped in the basin of the unit. One sloped ladder will be provided for NOTE: Upper Section of Unit Must Be Properly Oriented each cell.
  • Page 12 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Field Assembly of Working Platform and Ladder The working platform/ladder assemblies are shipped in the basin of the unit. In some cases they are shipped separately due to basin accessories that interfere with storage. The platform is partially assembled prior to shipment for minimal field assembly. The platform and ladder assembly should be attached after the unit is fully rigged following the instructions below.
  • Page 13 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Optional Motor and Gear Box Davit ATWB, eco-W and eco-WE 8.5’ 10’ and 12’ Wide Models A removable, dual point motor davit is provided on 8.5’ 10’ and 12’ wide models for both the Powerband Belt Drive System and the optional gear drive system (Figure 28.) This accessory is available to aid in the removal of fan motors and gear boxes.
  • Page 14 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler External Motor Installation 3’, 4’ & 8.5’ Wide Models (Note: 3’ & 4’ motors ship mounted) 1. Study Figure 31 before installing the motor base on the unit. 2. Insert the lifting device into “U” bolt A on motor base B. 3.
  • Page 15 General Information - Start-up & Maintenance Start-up Details Debris Clean all debris from the basin prior to start-up. Close and secure all access doors. Pump Discharge Line Connect the riser pipe from the pump discharge on the basin section to the riser pipe on the coil/fan section using the flexible connection and hose clamps provided.
  • Page 16 General Information - Start-up & Maintenance Maintenance Once the installation is complete and the unit is turned on, it is important that it be properly maintained. Maintenance is not difficult or time-consuming but must be done regularly to assure full performance of the unit. Refer to the maintenance instructions enclosed with the unit for proper maintenance procedures.
  • Page 17 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Accessory Location Checklist Accessories can ship in a variety of locations depending on the type of accessory, the size of the unit and the accessories purchased with the unit. See Table 6 for a guide to accessory location. Unit Accessories Shipping Location Aluminum Ladder...
  • Page 18 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Notes:...
  • Page 19 ATC-DC Condenser & eco-ATWB-H Closed Circuit Cooler Notes:...
  • Page 20 EVAPCO, Inc. • P.O. Box 1300 • Westminster, MD 21158 USA : 410-756-2600 • F : 410-756-6450 • E- : marketing@evapco.com HONE MAIL Printed on recycled paper ©2014 EVAPCO, Inc. using soy-based ink...