Electrical Requirements - KitchenAid KVWC956KSS0 Installation Instructions And Use And Care Manual

36" (91.4 cm) and 48" (121.9 cm) designer commercial-style
Table of Contents

Advertisement

Available languages

Available languages

Typical In-line Blower Motor System Venting Installations
C
D
B
A
A
A. 10" (25.4 cm) round vent
B. Mount on top of ceiling joists
C. Roof caps
D. Plywood (optional on some installations)
E. Mount on underside of roof rafters
F. Mount from cross-members tied to trusses
G. Duct horizontal; mount to cross-members tied to trusses
H. Wall cap
Calculating Vent System Length
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece
Equivalent Length
2.5'
45° elbow
(0.8 m)
5.0'
90° elbow
(1.5 m)
The maximum equivalent vent lengths are:
10" (25.4 cm) round vent - 60' (18.3 m)
Example vent system
90 elbow
6 ft (1.8 m)
2 ft
(0.6 m)
The following example falls within the maximum recommended
vent length.
One 90° elbow
One wall cap
8 ft (2.4 m) straight
Length of system
6
E
D
F
G
H
Wall cap
= 5.0 ft (1.5 m)
= 0.0 ft (0.0 m)
= 8.0 ft (2.4 m)
= 13.0 ft (3.9 m)

Electrical Requirements

Observe all governing codes and ordinances.
A
Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
(latest edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local
codes and ordinances.
A
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park Quincy,
A 120 V ~, 60 Hz, 463 W, AC only, 3.8 A, fused electrical
circuit is required.
If the house has aluminum wiring, follow the procedure
below:
Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper to
aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate.
The model/serial plate is located behind the filter on the rear
wall of the range hood.
Wire sizes must conform to the requirements of the National
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22. 1-94, Canadian Electrical Code, Part 1 and
C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
MA 02269-7471
CSA International 8501
East Pleasant Valley Road
Cleveland, OH 44131-5575

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kvwc958kss0

Table of Contents