17/28
Bosch Rexroth AG
Assembly
Min. 50 mm clearance area
Min. 25 mm clearance area
Min. 50 mm clearance area
Fig. 4: Required distances
7.2
necessary tools
No special tools are required for the assembly.
7.3
Recommended accessories
The following accessories are recommended for the connection of the VT-MSFA1
booster amplifier. These accessories are not included in the scope of delivery,
and can be ordered separately from Bosch Rexroth.
Table 5: Accessories
Component
Capacitor module VT11110-1X
Compact power supply unit VT-NE30-2X
7.4
Assembling the VT-MSFA1
For the assembly, observe the notices regarding applied standards and ap-
f
plication conditions in the data sheet.
Do not lay solenoid conductors and signal lines near power cables.
f
Used shielded cables (EMC-compatible) for signal and valve lines.
f
Do not use silicone-containing sealing, adhesive, or insulating agents.
f
Ensure a maintenance-friendly installation, i.e. simple access to the connec-
f
tion lines. Free access to the connection side must be guaranteed. The cable
ends should be sufficiently long so that the amplifier can also be dismounted
in the wired condition.
VT-MSFA1 | RE 30260-B/07.12
Min. 25 mm clearance area
Material number
R900020293