Connecting Power; Power Supply Connector Pin-Out - Siemens SIMATIC NET RUGGEDCOM M969 Installation Manual

Rugged ethernet switches
Table of Contents

Advertisement

Installing the Device
2.4 Connecting Power
The proper relay connections are as follows:
4
Figure 2.2
2.4

Connecting Power

The M23 power connector has five terminal pins, which means two power supply
sources are allowed to power the RUGGEDCOM M969 with the M23 power
connector. The RUGGEDCOM M969 supports dual redundant power supplies: Power
Supply 1 (PS1) and Power Supply 2 (PS2).
2.4.1

Power Supply Connector Pin-Out

The following is the pin-out for the M23 A-coded power supply connector:
M23 Power Supply Connector
1
2
Figure 2.3
12
1
2
3
Failsafe Alarm Relay Wiring
5
4
3
M23 Power Supply Connector
Terminal #
1
PS1 Live/+
2
PS1 Neutral/-
3
Chassis Ground
 
Description
PS1 Live/+ is connected to the positive (+)
terminal if the power source is DC or to the (Live)
terminal if the power source is AC.
PS1 Neutral/- is connected to the negative (-)
terminal if the power source is DC or to the
(Neutral) terminal if the power source is AC.
Chassis Ground is connected to the Safety Ground
terminal for AC inputs or the equipment ground
Pin
Description
1
Normally Closed
2
Common
3
Normally Open
Usage
Installation Manual, 01/2021, C79000-G8976-1039-03