Responsive Respiratory Respond O2 Operation Manual

Responsive Respiratory Respond O2 Operation Manual

Ultrasonic oxygen indicator

Advertisement

Quick Links

Respond O
2
Ultrasonic Oxygen Indicator
Operation Manual
RESPONSIVE RESIRATORY, INC.
Responsive Respiratory, Inc.
6244 Lemay Ferry Rd.
6244 Lemay Ferry Rd.
St. Louis, MO 63129
St Louis, MO 63129
Phone: 866-333-4030
sales@respondo2.com
Fax: 866-333-4035
www.respondo2.com
sales@respondo2.com
866-333-4030
www.respondo2.com
803350 Rev. B
October 2020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Respond O2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Responsive Respiratory Respond O2

  • Page 1 Respond O Ultrasonic Oxygen Indicator Operation Manual RESPONSIVE RESIRATORY, INC. Responsive Respiratory, Inc. 6244 Lemay Ferry Rd. 6244 Lemay Ferry Rd. St. Louis, MO 63129 St Louis, MO 63129 Phone: 866-333-4030 sales@respondo2.com Fax: 866-333-4035 www.respondo2.com sales@respondo2.com 866-333-4030 www.respondo2.com 803350 Rev. B...
  • Page 2 Dead, defective battery Water or water vapor has been introduced into unit. Responsive Respiratory will, at its option, have the unit repaired or replaced. If repair is authorized, Responsive Respiratory will not charge for parts or labor. Purchaser will be responsible for all shipping charges to return the unit to Responsive Respiratory.
  • Page 3: Table Of Contents

    Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator WARNING NOTES OPERATION MANUAL USAGE: The Respond O ™ Ultrasonic Oxygen Indicator is designed CONTENTS for intermittent usage to determine the oxygen concentration produced by an oxygen concentrator. It may also be utilized to do spot Warning Notes checks of gaseous or liquid oxygen.
  • Page 4 Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator TROUBLE SHOOTING CHECKLIST (CONTINUED) TROUBLE SHOOTING CHECKLIST Suggested Suggested Complaint Probable Cause Complaint Probable Cause Corrective Action Corrective Action Display is blank Bad batteries. Replace batteries. Ensure U.S.P. when unit is turned Corroded battery Clean battery terminals.
  • Page 5: Introduction

    Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator INTRODUCTION INITIAL SETUP ™ ™ Thank you for purchasing a Respond O Ultrasonic Oxygen Indicator. 1. Remove the Respond O Ultrasonic Oxygen Indicator from The designers of this product have years of experience in the field of the package.
  • Page 6 Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator FREQUENTLY ASKED QUESTIONS FREQUENTLY ASKED QUESTIONS (continued) The following are some of the frequently asked questions about the When I am in the Concentrator Mode and hook the unit up to a U.S.P. operation of this device. oxygen(>...
  • Page 7: Instructions For Checking Oconcentrators

    Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator INSTRUCTIONS FOR CHECKING O CONCENTRATORS INSTRUCTIONS FOR SPOT CHECKING LIQUID OXYGEN VESSELS or OXYGEN CYLINDERS To turn unit on and off: To turn the unit on or off press and release the “on/off” button on the lower left-hand side of the unit. (EXAMPLE: The Respond O ™...
  • Page 8 Ultrasonic Oxygen Indicator Ultrasonic Oxygen Indicator UNIT SPECIFICATIONS ENVIRONMENTAL EFFECTS General Specifications Temperature Under normal operating conditions 32º F to 105º F (0º C to 41º C), the Physical Data unit's microprocessor and temperature circuit will compensate for Dimensions: 3.60" W x 5.75" H x 1.29" D variations in temperature.
  • Page 9: Verification & Calibration Instructions

    (eg. < 98% or >102%) unit will not “Quick Cal” and the Full Two Step procedure on O2/calibrate” button or the unit will shut off automatically. the following page must be followed. If any problems are encountered during the calibration sequences, contact Responsive Respiratory at 1-866-333-4030.
  • Page 10: Maintenance

    Ultrasonic Oxygen Indicator MAINTENANCE Battery Replacement When the LCD displays "LO BATT" in the lower left corner, the battery is low and should be replaced. A spare battery is supplied with your unit. ™ NOTE: The Respond O must be removed from the carrying case to replace battery.

Table of Contents