Resetting The Inlet Position - Airstream TC5-ITA User Manual

Table of Contents

Advertisement

TC5-ITA

Resetting the Inlet Position

Resetting the actuator's position allows clearing all accumulated time offets
caused by the frequent openings and closings of the inlet. It is highly sug-
gested to reset the inlet positions frequently to make sure they are always
accurate.
Choose a Resetting Method:
The inlet reset can be done in two different ways:
1. Reset the minimum position only:
The inlet closes during the Reset Time Delay each
time a reset is performed. Once the inlet position is
reset, the inlet returns to its previous position. Set
internal switch #8 to OFF to use this reset method.
2. Reset toward the nearest position
Each time a reset starts, the inlet panel is directed
towards the closest position from its current open-
ing: it then opens or closes during the Reset Time
Delay. Once the reset is completed, the inlet returns
to its previous position. This function prevents clos-
ing the air inlet when the room temperature already
asks for a large opening of the panel. Set internal
switch #8 to ON to use this reset method.
24
TC5-ITA rev.02
This resetting method requires the pres-
ence of limit switches at both ends of
the actuator.
ON
OFF
ON
OFF

Advertisement

Table of Contents
loading