7.3.4.4 F167_HighSpeedCounter_Reset, Target Value Match OFF

If the elapsed value of the high-speed counter matches the target value, an interrupt process
immediately turns the specified output to FALSE.
Characteristics of target value match OFF control
0
-200
2
3
4
-200
Target value
Elapsed value of high-speed counter
1
Execution condition
2
High-speed counter control flag
3
PLC output
4
The PLC output turns to FALSE when the elapsed value matches the target value. In addition, the high-speed
counter control flag turns to FALSE and the instruction is deactivated.
REFERENCE
Please refer to the FPWIN Pro online help for details and a programming
example.

7.3.5 Sample Programs

The following programming examples demonstrate how to make control code settings and
how to use the high-speed counter instructions.
The FPWIN Pro projects in LD and ST code can be downloaded from the Panasonic Web site
(http://www.panasonic-electric-works.com/peweu/en/html/22164.php).
The programming examples for this chapter can be found in
pe_63403_0001_sample_high_speed.zip.
These examples can be used with different PLC types. Therefore you have to adapt the PLC
type in the FPWIN Pro Navigator.