Tonkaflo Specifications; Capacities; Tonkaflo Pump Capacities - GE OSMONICS TONKAFLO SS Series Installation, Operation And Maintenance Manual

High-pressure centrifugal pumps with e-bearing frames
Table of Contents

Advertisement

2.0

TONKAFLO SPECIFICATIONS

The Tonkaflo pumps covered in this instruction manual are the higher capacity SS5500,
SS8500, SS12500, SS23000, and SS24000 Series pumps. These five series of pumps cover a
flow range of 20 - 300 gpm (4.5 - 68 m
The capacity and discharge pressure can be increased by operating pumps in parallel or
series, respectively. There is no maximum limit on capacity when operating Tonkaflo pumps
in parallel. When operating pumps in series, a maximum discharge pressure of 1000 psig (69
barg) may be achieved with optional high pressure construction on the downstream pump.
With inlet pressures greater than 200 psig (13.8 barg) and less than 400 psig (27.6 barg),
optional high-pressure mechanical seals should be used.
2.1

Capacities

3500 rpm - 60 Hz
SS
Minimum - Maximum
Series
gpm (m
5500
20 - 75 (4.5 - 17.0)
8500
30 - 100 (6.8 - 522.7)
12500
40 - 190 (9.1 - 43.1)
23000
80 - 300 (18.2 - 68.1)
24000
80 - 300 (18.2 - 68.1)
NOTE:
There must be adequate flow through the pump to prevent excessive heat build-
up at all times.
3
/h) with single-unit pressures up to 650 psig (44.8 barg).
Tonkaflo Pump
Maximum
Number
3
/h)
of Stages
60 Hz
24
27
22
11
16
Table 2.1
Capacities
2900 rpm - 50 Hz
Minimum - Maximum
3
gpm (m
/h)
15 - 65 (3.4 - 14.8)
20 - 90 (4.5 - 20.4)
35 - 160 (7.9 - 36.3)
65 - 25 (14.8 - 56.8)
65 - 250 (14.8 - 56.8)
2
Maximum
Maximum
Number
Efficiency
of Stages
50 Hz
33
60%
33
64%
27
62%
16
61%
18
61%