Dimensions For Exhaust Connection - Miele PWT 6089 Vario Operating And Installation Instructions

Washer-extractor and tumble dryer stack
Hide thumbs Also See for PWT 6089 Vario:
Table of Contents

Advertisement

Calculation example
A
Wall pipe, with louvred vent
= 1 x 12' 6" (3.8 m)
Additional duct length
B/D 2 bends, 90° plastic piping
= 2 x 2' 7 1/2" (0.8 m)
Additional duct length
C
0.5 m plastic piping
= 0.5 x 3' 3" (1 m)
Additional duct length
Total duct length
Result: A duct diameter of 4" (100 mm)
is adequate as the total duct length is
less than the 66' (20 m) specified in
Table II.
Installation - extraction ducting
= 12' 6" (3.8 m)
= 5' 3" (1.6 m)
= 1' 8" (0.5 m)
= 19' 5" (5.9 m)
Dimensions for exhaust
connection
View from above
Rear view of the dryer
89