10.7 Fresh Water Connection
Make sure that the gaskets are inserted.
1. Connect the water inlet hose with the angled
end to the appliance (Fig. 10-12. Tighten the
screw joint by hand.
2. The other end connect to a water tap with a
3/4" thread (Fig. 10-13).
Note: Aqua-stop-system
Some models are equipped with an aqua-stop inlet hose (B).The aqua-stop system
protects against water damage by automatically cutting the fresh water supply in case
of a leaking hose. This is indicated by a red marker (C). The hose must be replaced. .
10.8 Electrical Connection
Before each connection check if:
▶ power supply, socket and fusing are appropriate to
the rating plate.
▶ the power socket is earthed and no multi-plug or
extension are used.
▶ the power plug and socket are strictly according.
Put the plug into the socket (Fig. 10-14).
WARNING!
▶ Ensure always that all connections (power supply, drain and fresh water hose) are fi rm,
dry and leack free!
▶ Take care these parts are never to be crushed, kinked, or twisted
▶ If the supply cord is damaged, it must be replaced by the service agent (see warranty
card) in order to avoid a hazard. .