INSTALLATION INSTRUCTIONS

Electrical connection
Before connecting the appliance, make sure:
1. the mains voltage in your home matches that specified on the appliance dataplate;
2. the electrical system adequate for appliance max. power absorption specified on the dataplate;
3. the house electrical system is suitably earthed.
• Connect the appliance to the power supply by means of a suitable disconnecting switch with
min. contact opening distance allowing complete disconnection in category III overvoltage
conditions, in compliance with the installation regulations.
Notes: After installation, the electrical components must only be accessible with the use of a special tool.
The power cable must be H05VV-F type and electric connections must be in compliance with below
electric information.
3 x 2.5 mm² 220 V ~ 50 Hz
3 x 2.5 mm² 230 V ~ 50 Hz
3 x 2.5 mm² 240 V ~ 50 Hz
Instructions for the installer
Warning
• Disconnect the appliance from the power supply before carrying out any repairs or
operation.
• Installation must be carried out by a qualified technician, in compliance with the current
safety regulations.
• The appliance must be earthed.
The Manufacturer declines any liability for injury or damage to people or property due to non-compliance
with the above-mentioned regulations. The appliance dataplate is located at the bottom right of frame of
the oven cavity and visible with the door open. Adjustment conditions are given on a label on the packing.
Do not use the oven door for handling operations, or for removing the appliance from the packing.

ELECTRICAL CONNECTION AND SAFETY

For the electrical connection, make sure to follow the instructions given below:
• The earth wire must be connected to the earth terminal (
electrical outlet in the place where the appliance is to be installed, immediately contact to our
Authorised Service.
• The earthed electrical outlet must be close to the appliance. Do not use extension cords.
• The power cable must not touch hot parts of the product.
• If the power cable is damaged, contact a Qualified Service Centre. The cable must be replaced by the
Authorised Service.
• An incorrect electrical connection could damage your appliance. Such damage is not covered by the
warranty.
• The appliance is arranged for a 230 Volt power supply. If the power supply voltage is different,
immediately contact to our authorised service.
The power cable must not touch hot parts of appliance, otherwise it may become damaged.
This situation could cause short circuiting.
The manufacturer declines any liability for damage and loss due to failure to comply with the following
safety regulations.
68
5 x 1.5 mm² 380 V~, 3N 50 Hz
5 x 1.5 mm² 400 V~, 3N 50 Hz
5 x 1.5 mm² 415 V~, 3N 50 Hz
). If there is no approved earthed