The wine conditioning unit is supplied
with a mains cable with moulded plug
ready for connection to an earthed
socket.
The socket must be easily accessible
after the wine conditioning unit has
been installed. If the socket is not easily
accessible, ensure that a suitable
means of disconnection is provided on
the installation side for each pole.
Risk of fire from overheating.
Connecting the refrigeration appli-
ance to a multi-socket plug adapter
or to an extension lead can overload
the cable.
For safety reasons, do not use an ex-
tension lead or multi-socket adapter.
The electrical system must comply with
local and national safety regulations
(BS 7671 in the UK).
For safety reasons, we recommend us-
ing a type  residual current device
(RCD) in the assigned electrical installa-
tion for connecting the wine condition-
ing unit.
If the mains connection cable is dam-
aged, it must only be replaced with a
specific mains connection cable of the
same type (available from the Miele
Customer Service Department). For
safety reasons, such replacement may
only be carried out by a qualified spe-
cialist or the Miele Customer Service
Department.

Electrical connection

These operating instructions and the
data plate indicate the nominal power
consumption and the appropriate fuse
rating. Compare this information with
the data of the on-site electrical con-
nection.
If in any doubt, consult a qualified elec-
trician.
Do not connect the wine conditioning
unit to a stand-alone inverter such as
those used with an autonomous power
supply, e.g. solar power. When the wine
conditioning unit is switched on, power
surges could result in an auto switch-
off. This could damage the electronic
module.