6.2 Piping position
When routing the piping and wiring from the left side of the unit, removal of the chassis cut-outs is
necessary.
1.
Remove cut-out 1 when routing the wiring only;
Remove both cut-out 1 and 2 when routing both the wiring and piping.
2.
Take out the piping from body case, wrap the piping electric wire, water pipe with tape and pull them through the piping hole.
L - Left
6.3 Mounting slots
Hinge the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough.
Please note: the height of the installed location should be 2,5 m or more from the floor.
CAUTION: THE PIPING CAN BE LEAD OUT FROM LEFT SIDE OR REAR LEFT.
LR – Left rear
A – Fixing hook
B – Mounting plate
1.
Inlet water side pipe
2.
Outlet water side pipe
3.
Inlet side piping insulation
11
4.
Final wrapping
5.
Water drainage pipe
6.
Outlet side piping insulation