AEG ME09 Installation, Operation And Maintenance Manual page 61

5000a-6400a
Table of Contents

Advertisement

131
8
132
8
133
8
134
8
135
1
16
136
2
16
137
8
8
138
8
139
8
140
8
141
8
142
8
143
8
144
8
145
1
16
146
2
16
147
9
8
148
8
150
8
151
8
152
8
153
8
154
8
155
1
16
156
2
16
157
10
8
158
8
159
8
160
8
161
8
162
8
163
8
164
8
165
1
16
166
2
16
167
8
168
8
169
8
170
8
179
1
8
180
2
8
196
8
227
1-
228
229
230
231
232
233
234
235
236
237
238
1
10
239
0-
102
-
103
-
104
-
105
EPROM
-
107
BIM
-
108
0-
109
0-
112
1
0-
113
2
0-
116
-
117
EPROM
-
118
-
0-
1-
2-
5
1-
1-
1-
1-
TRIP UNIT
Communica on register
ENGLISH
Communications Parameters Function 2
Reg.
Variable
Value
5
Relay 1 Status
0- OFF, 1- ON
6
Relay 2 Status
0- OFF, 1- ON
9
Input 1 Status
0- OFF, 1- ON
10
Input 2 Status
0- OFF, 1- ON
27
Breaker position
0- OFF, 1- ON
34
Cassette Indication
0- OFF, 1- ON
35
Draw Out
0- OFF, 1- ON
44
Remote Close
0- OFF, 1- ON
Communications Parameters Function 3
2
GF Protection Sum Enable
0-Disable, 1-Enable
5
No. of Poles
0-3 Pole, 1- 4 Pole
7
Full Metering Enable
0-Disable, 1-Enable
8
Neutral Position
0-Disable, 1-Enable
10
Long Time Protecti. Enable
0-Disable, 1-Enable
18
Agency Standard
0-UL, 1-IEC, 2-ANSI
19
Breaker type
8- EntelliGuard
20
GTU Model Type
4-GTU ACB
22
Current Sensor Rating
1-150A
2-200A
3-225A
4-400A
5-600A
6-800 A
7-1000A
24
0-No
Ground Fault SUM Alarm Enable
31
Current Alarm Enable
0-No
35
ZSI Enable
0-Disable,
37
MCR Level Low 16 bits
---
38
MCR Level High 16 bits
---
39
HSISC Level Low 16 bits
---
40
HSICS Level High 16 bits
---
81
Instantaneous
0-Disable,
98
Breaker Serial Number - Low 16 bit
99
Breaker Serial Number - High 16 bits
107
Reduce Instantaneous
0- Disable,
202
EntelliGuard Ie setting
0- Unde ned
1- 250,
2 - 280,
3 - 315,
4 - 350,
5 - 400,
6 - 450,
7 - 500,
8 - 560,
9 - 605,
10- 610,
11- 615,
12 - 630,
13 - 720,
14 - 768,
15 - 776,
16 - 784,
17 - 800,
18 - 900,
19 - 960,
20- 970,
21- 980,
22 -1000,
206
Neutral Pole Rating
0-50% ,
207
ZSI Combination
0
1-GF
2-GF&ST
3-ST
208
PT Primary Voltage
120- 600
209
PT Connection
0- Ph-N
210
Password Protection
0 to 20
211
Modbus Slave Address
8 bit value
213
Comm. Setting
0- 300-8N2
1- 600-8N2
2- 1200-8N2
3- 2400-8N2
4- 4800-8N2
Read/Write
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
Read
8-1200A
15-5000A
Read
9-1600A
16-6000A
10-2000A
17-630A
11-2500A
18-1250A
12-3000A
19-6400A
13-3200A
20-Universal spare
14-4000A
1-YES
Read
1-YES
Read
1-GT-ST (Z), 2-GR-ST-Inst (T)
Read
Read
Read
Read
Read
1-15X Switchable.
Read
-
Read
-
Read
1-Enable
Read
23 - 1125,
46 - 3072,
Read&Write
24 - 1196,
47 - 3104,
25 - 1210,
48 - 3136,
26 - 1225,
49 - 3200,
27 - 1250,
50- 3840,
28 - 1280,
51- 3880,
29 - 1440,
52 - 3920,
30- 1536,53 - 4000,
31- 1552,54 - 4800,
32 - 1568,
55 - 4850,
33 - 1600,
56 - 4900,
34 - 1800,
57 - 5000,
35 - 1920,
58 - 6144,
36 - 1940,
59 - 6208,
37 - 1960,
60- 6272,
38 - 2000,
61- 6400,
39 - 2250,
62 - 160,
40- 2400,63 - 180,
41- 2425,64 - 380,
42 - 2450,
65 - 385,
43 - 2500,
66 - 390,
44 - 2560,
45 - 2880,
1-63% ,
2-100%
Read&Write
4-Instantaneous
5-GF and Inst
7-GF, ST and Inst
Read&Write
1- Ph-Ph
Read&Write
16- Lock
19- Unlock Read&Write
Read&Write
7- 300-801
14- 300-8E1 Read/Write
8- 600-801
15- 600-8E1
9-1200-801
16-1200-8E1
10-2400-801
17-2400-8E1
11-4800-801
18-4800-8E1
2.5-03
2
.5

Advertisement

Table of Contents
loading

Table of Contents