Operating Instructions
READ STATUS
INSTALLED
2=POTS SETTINGS
3=IP SETTINGS
Communicator Screen #1
COMMUNICATOR
1=PRI COMM PATH
2=SEC COMM PATH
TBL REPORT LIMIT
Communicator Screen #2
Pressing 1 for POTS indicates whether the receiver has been enabled or disabled. It also provides information on the receiver such as:
Account Code
Phone Number Prefix
Phone Number
Communication Format
Pressing 2 for Ethernet indicates whether the receiver has been enabled or disabled. It also provides information on the receiver such as
CS account info.
Pressing 3 for Cellular indicates whether the receiver has been enabled or disabled. It also provides information on the receiver such as
the CS account.
COMMUNICATOR
1=EVENT CODES
TEST TIME INT
24HR TEST TIME
Communicator Screen #3
COMMUNICATOR
REPORT STYLE
POINT
Communicator Screen #4
4.23.11 Print
READ STATUS
1=FUTURE USE
2=PRINT
3=TIME/DATE
Read Status Screen #5
Pressing 1 while viewing Print Screen #1 allows the user to print the History file which will detail all of the system activities since the
file was last cleared from memory.
Pressing 2 while viewing Print Screen #1 allows the user to print the Walktest log which will detail all of the system activations during
walktest since the log was last cleared.
Pressing 3 while viewing Print Screen #1 allows the user to print the Walktest summary which will list the total of each type of input
activation.
Pressing 1 while viewing Print Screen #2 allows the user to print the detector data for each addressable smoke detector connected to the
system. A printout, similar to the following example, will be generated if an optional printer is connected to the FACP.
DEVICE #
1D001
1D002
1D003
1D004
1D005
1D006
1D007
1D008
114
Pressing 3 for IP Settings while viewing Communicator Screen #1 will display settings for the ethernet por-
YES
tion of the Communicator. The screen will indicate if DHCP has been enabled Yes or disabled No. If the
DHCP has not been enabled, the Static Settings will be displayed.
Communicator Screen #2 allows the programmer to press 1 to view the Primary Communication Path set-
tings or 2 to view the Secondary (backup) Communication Path settings for the Communicator and indi-
cates the Call Limit for Communicator trouble calls within a 24 hour period.
0
Pressing 1 while viewing Communicator screen #2 will cause the following screen to be displayed:
Communicator Screen #3 allows the user to view the Event Codes for the chosen communication format as
well as the Test Time Interval and 24 Hour Test Time.
24
0100
Communicator Screen #4 allows the user to viewwhether the reporting style is by Point or Zone.
To print program data or control panel status, press 2 while viewing Read Status Screen #5. The following
screens will be displayed:
PRINT
1=HISTORY
2=WALKTEST LOG
3=WALKTEST SUMMARY
Print Screen #1
DEVICE TYPE
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
SMOKE (PHOTO)
COMMUNICATOR
1=POTS
2=ETHERNET
3=CELLULAR
% DRIFT COMP
CHAMBER
20
1281
20
1281
21
1259
20
1309
21
1281
20
1322
20
1280
20
1215
NFW-50X Manual — P/N LS10129-001NF-E:C 7/25/2018
PRINT
1=DETECTOR DATA
2=COMM SETTINGS
3=EXIT PRINTING
Print Screen #2
TIME/DATE
12:01 AM 01-08-2016
12:01 AM 01-08-2016
12:01 AM 01-08-2016
12:02 AM 01-08-2016
12:02 AM 01-08-2016
12:02 AM 01-08-2016
12:02 AM 01-08-2016
12:02 AM 01-08-2016
Read Status