z EV scale
The EV scale on the LCD monitor and in the viewfinder indicates the difference between the standard
exposure (0.0 EV) determined by the camera meter and the set exposure determined by the shutter speed,
and the aperture specified by the photographer (Metered Manual).
LCD
monitor
Viewfinder
: Metered Manual
• If the exposure is adjusted, the standard exposure (0.0 EV) is shifted by just the corresponding amount of
the adjustment.
z How to use the AEL button in manual mode
While you press and hold the AEL (AE lock) button, the exposure determined by the meter is locked as the
standard exposure (0.0 EV). When you recompose your shot with the AEL (AE lock) button pressed, an
exposure value within the spot metering circle appears as the second standard index.
The following illustrations show a case where the set exposure specified by the photographer is 1.0 EV
more than the locked standard exposure determined by the meter. When the composition is changed in the
viewfinder, the exposure within the spot metering circle is 0.7 EV more than the set exposure, thereby
making it 1.7 EV more than the standard exposure determined by the meter.
42
The set exposure
specified by the
photographer is the same
as the exposure
determined by the meter.
The exposure specified
by the photographer
The exposure within the
spot metering circle
when you recompose
your shot.
The set exposure
specified by the
photographer is 1.0 EV
more (+) than the
standard exposure
determined by the meter.
Spot metering circle
The b B arrow appears if
the set exposure is
beyond the range of the
EV scale. The arrow
starts flashing if the
difference becomes
greater.