Start-up and Service
6
Purge memory (in case of The Advantage Series or Encore 300 dispensers, install the coldstart
jumpers and perform a coldstart).
The FlexPay EPP may not enable proper debit functions if the purge memory or
coldstart procedure is not performed.
When the dispenser comes up, enter the CRIND Diagnostic Mode, program the CRIND IDs,
7
CRIND Mode, and enable any peripheral devices (Cash Acceptors, TRIND
Encore 500 and Eclipse dispensers, refer to
Diagnostic Card"
to
"Entering Diagnostic Mode Using the CRIND Diagnostic Card"
Bring the POS back online by re-connecting the Two-wire cable or by de-isolating at the
8
D-Box.
9
After the download is complete, run a Keypad test (For Encore 500 and Eclipse units, refer to
"Performing the Keypad Test"
refer to
10
Check if debit transactions are accepted using the newly installed FlexPay EPP.
Temperature Range
Operating Temperature Range
Storage Temperature Range
Note: For security reasons, the encryption keys will be deleted and the FlexPay EPP will not
Built-in Battery Life
The battery has a minimum life of 5 years; it is indefinite when powered on.
Note: Do not replace or tamper with the battery. If the battery is tampered with, information
Page 12
IMPORTANT INFORMATION
on
page 15
and for Encore 300 and The Advantage Series dispensers, refer
"Performing the Keypad Test"
-30 °C to +70 °C
-40 °C to +70 °C
work, if the temperature is outside the storage range.
about the keys will be erased and the FlexPay EPP will have to be replaced. The battery
is a non-replaceable part.
MDE-4784D FlexPay™ Encrypting PIN Pad Start-up and Service Manual · December 2011
"Entering Diagnostic Mode Using the CRIND
on
page 16
and for Encore 300 and The Advantage Series units,
on
page
18).
Temperature Range
, and so on). For
®
on
page 18
.