Verifying A Single Manual Tuning; Adjusting Pdm Values For Agcs And Afc - Nokia RH-10 Series Troubleshooting Manual

Hide thumbs Also See for RH-10 Series:
Table of Contents

Advertisement

CCS Technical Documentation

Verifying a Single Manual Tuning

Open the "RF Tuning" dialog box, shown here.
Note: The tuning descriptions given in the Tuning section describe the tuning process and provide
information as to what values will be returned to you from the phone, if any.
According to these descriptions, click "Self-Tuning" for self tunings or "RF Tuning" for the
others. Choose the appropriate test from the "Tuning Names" list. Values that you must
enter are entered into the Values subwindow. If more than one value is entered, enter a
delay time (in seconds) in the Delay (Sec) field. This indicates the delay between applica-
tions of the multiple values entered. Three seconds is sufficient time for all tests to run;
however, in certain cases, you may want to increase the delay in order to closely observe
the phone's behavior during the tuning.
Any data returned from the phone is displayed on the status line (the grayed box at the
bottom of the dialog box). If no tuning value is returned, this line will indicate if the tun-
ing was successful or not.
To begin a tuning, click the Tune button.

Adjusting PDM Values for AGCs and AFC

The following "PDM Control" dialog box has several sliders—one each for each of the
AGCs and the AFC. Use your mouse to move the slider pointer to the value that you want
to set. (Values are indicated in decimal format.) When completed, click the Set button.
(Alternatively, you can click the up and down arrows next to the value fields below the
sliders. This will increase or decrease the value one step at a time. If you use this method,
you do not have to click the Set button.)
Issue 1 09/2002
Nokia Corporation
Confidential
RH-10
Troubleshooting
Page 33