Maintenance Intervals - Siemens VersiCharge Ultra 175 Maintenance Manual

175 kw dc fast charger
Hide thumbs Also See for VersiCharge Ultra 175:

Advertisement

Maintenance intervals

Key
C = Check, R = Replace
User unit
Part
Liquid cooling system
Charge plug/cable
Coolant pump (front)
Radiator fans (x2)
Isolated power unit
Part
Front door filters
Primary Transformer
Rear door fans + filter (x2)
UPS battery
Notes:
1. Filter cleaning/replacement is environment dependent. Perform more frequently in higher pollution environments.
2. Used batteries must be disposed of in accordance with applicable national and local environmental regulations.
They can also be returned to the manufacturer.
All units
Part
Tilt sensor/door switches
Electrical safety checks
Test
Coolant level inspection
Inspect cable and plug
Check for operation
Inspect and clean
Test
Check filter
Inspect electrical
connections for signs of
heat or corrosion
• Check filter
• Check for airflow
Check battery controller for
alerts/alarms
Test
Verify correct operation
Maintenance Manual
Action
If too low, top off
Inspect cable and plug
Periodic replacement
Clean/replace as
required (1)
Action
Clean/replace as
required (1)
Ensure connections are
tight and firm
Clean/replace as
required (1)
Check and replace batteries
as required
Action
If it does not operate
correctly, troubleshoot
See section
Electrical Safety Checks
| VersiCharge Ultra 175™
12 mth
2 yr
5 yr
C
C
C
R
C
R
12 mth
2 yr
10 yr
C
R
C
C
R
C
12 mth
2 yr
5 yr
C
C
R
5