hertz relationship. The motor must rotate CCW (counter clockwise) when viewed from the opposite
drive end when rotating in the forward direction. If the motor's direction of rotation is incorrect, this
must be corrected by reversing any two motor leads either at the G7 or the motor.
The programming example demonstrates the programming required when using a bi-directional,
differential line driver encoder providing 1024 pulses per revolution.
Programming
Direct
Parameter Path
Access
F014
Program Fundamental
Parameters Frequency Setting
F411
Program Motor Parameters Motor
Settings
F412
Program Motor Parameters Motor
Settings
F413
Program Motor Parameters Motor
Settings
F400
Program Motor Parameters Vector
Motor Model
F367
Program Feedback Parameters PG
Settings
F368
Program Feedback Parameters PG
Settings
F702
Program
Utility Parameters
Units
FXXX
Program Special Control Parameters
Frequency Control
F115
Program Terminal Selection Input
Terminals
F420
Program Torque Setting
Parameters Torque Control
F214
Program Torque Setting
Parameters Setpoints
F425
Program Torque Setting Torque
Speed Limiting
F426
Program Torque Setting Torque
Speed Limiting
F427
Program Torque Setting Torque
Speed Limiting
F428
Program Torque Setting Torque
Speed Limiting
(39) Place G7 in local control mode
(40) Using the EOI, give the G7 a 1Hz frequency setpoint
(41) Press Run
For additional assistance, please contact Toshiba Adjustable Speed Drive Marketing Dept. at (800) 872-2192
efesotomasyon.com -Toshiba inverter,drive,servo,plc
Parameter Name
V/f Pattern
Number of Motor Poles
Rated Capacity of Motor
Motor Type
Autotune
Number of PG Input
Pulses
PG Input Phases
Display
Frequency Display
Resolution
Start-up frequency
S1 (or other discrete input
terminal)
Torque Command
Selection
RR
Forward Speed Limit
Selection
Forward Speed Limit
Level
Reverse Speed Limit
Selection
Forward Speed Limit
Level
Comments
Select either 'PG Vector Control
(speed/torque switching)'
Configure the number of motor poles to
match that of the motor used
Rated capacity of the motor is kW. To
determine kW if Hp is known, multiply Hp
by 0.745
If motor used is not listed as a possible
selection, use 'Other'. and perform autotune
as last step.
Select 'Reset Motor Defaults'. The G7 will
then apply the correct motor model.
1024 (set to match PPR of encoder)
2 (use 1 if using non directional encoder)
Change to 0.01
Set to 0.00 to allow the G7 and motor to
produce holding torque at zero speed
Select #56: Control Switch (torque,postion)
Set to source of torque command. RR used
is this example
Scale RR input as required.
Select 'SETTING'
Set to desired maximum output frequency in
forward direction while in torque control
mode
Select 'SETTING'
Set to desired maximum output frequency in
reverse direction while in torque control
mode
44