DXV AT200®LS SpaLet®
TROUBLESHOOTING GUIDE

No operation

1. Is the power plug inserted properly into the outlet?
2. Is the power outlet a GFCI AC 110V/120V? Pg. 5 in manual.
a. Is the outlet hot? Check power by plugging in a different item, such as a blow dryer.
3. Is the person seated while trying to operate? The seat sensor must be covered to operate. Pg. 15
4. Is the angle stop fully opened? Pg. 46 in manual.

Remote Control Operation cannot be performed

1. Is the power on the remote turned on? Pg. 48 in manual
2. Are the batteries working? Pgs. 5 & 48 in manual
a. Do they need to be replaced? Batteries should be changed annually or as needed.
b. Did replacing batteries correct the issue?
c. Are you getting an error message on the LED screen
3. Is a remote control other than the supplied one is being used. When a replacement remote
is used it needs to be registered to the SpaLet, see pg. 49 in user manual. (The remote control
is not registered correctly.)

The Spray Nozzle Does Not Come Out

1. Is the angle stop fully opened? Pg. 46 in manual.
2. Is the person seated while trying to operate?
3. Is the filter clogged? The filter is in the angle stop. Pg. 47 in manual.

The Nozzle Comes Out, but the Shower is Weak

1. Is the angle stop fully opened? Pg. 46 in manual.
2. Is the filter clogged? The filter is in the angle stop. Pg. 47 in manual.
3. Is the spray strength set appropriately? Use the

The Nozzle Comes Out, but the Shower Does Not Come Out

1. Is the angle stop fully opened? Pg. 46 in manua.l
2. Is the person seated while trying to operate? The seat sensor must be covered to operate. Pg. 15
3. Is the filter clogged? The filter is in the angle stop. Pg. 47 in manual.
The Spray Position is Inappropriate or Does Not Hit the Right Spot
1. Has the position been adjusted by pressing the
a. Depending on how the user sits on the seat, the nozzle position will hit different areas. If the
customer only sits half way on the seat then the right area may not be reached. It is best if
they adjust their sitting position to fit within the reach of the nozzle.

The Water Spray is Too Cold or Too Hot

1. Water temperature settings are adjusted through the control panel on the remote control?
Pg 15. in manual
©2018 AS America Inc.
+
-
&
on remote to adjust strength.
&
arrows on the remote? Pg 15. in manual
Page 1
7/18
www.dxv.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AT200 LS SpaLet and is the answer not in the manual?

Questions and answers

Kathryn Jo Crowder
July 6, 2025

The lid starts to open and then closes

Maureen Hiller
May 16, 2025

The spray nozzle does not retract completely and sprays whenever someone sits down

User image 6827c08f1dfcd
1 comments:
Mr. Anderson
May 22, 2025

If the spray nozzle does not retract completely and sprays when someone sits down, first ensure the remote control is registered correctly to the SpaLet. Also, check if the seat sensor is functioning properly, as it must detect someone seated to operate correctly. If the issue persists, inspect the angle stop to confirm it is fully opened and check the filter in the angle stop for clogs.

This answer is automatically generated

Kathryn Jo Crowder
July 6, 2025

Please send recalibration instructions

Subscribe to Our Youtube Channel

Summary of Contents for DXV AT200 LS SpaLet

  • Page 1 DXV AT200®LS SpaLet® TROUBLESHOOTING GUIDE No operation 1. Is the power plug inserted properly into the outlet? 2. Is the power outlet a GFCI AC 110V/120V? Pg. 5 in manual. a. Is the outlet hot? Check power by plugging in a different item, such as a blow dryer.
  • Page 2 DXV AT200®LS SpaLet® TROUBLESHOOTING GUIDE The Seat / Seat Lid Does Not Slow Down 1. Has the performance changed over time; did it slow close at some point? a. If the seat performance has changed over time, then the slow close feature may need to be replaced.
  • Page 3 DXV AT200®LS SpaLet® TROUBLESHOOTING GUIDE Warm Air Does Not Come Out 1. Is the user seated while trying to operate? The seat sensor must be covered for functions to operate. Pg 52 in manual. 2. Air temperature adjustments can be made through the remote control panel. Pg. 18 Warm Air is hot 1.

Table of Contents

Save PDF