CONTENTS OF FUNCTION SETTING
Follow the instructions in the Local Setup Procedure, which is supplied with the remote control, in
accordance with the installed condition.
After the power is turned on, perform the Function Setting on the remote control.
The settings may be selected between the following two: Function Number or Setting Value.
Settings will not be changed if invalid numbers or setting values are selected.
1-1
1-2
1-3
Cooler room temperature correction
1-4
Heater room temperature correction
1-5
1-6
Indoor Room Temperature Sensor Switching Function
1-1.Settingthefiltersign
The indoor unit has a sign to inform the user that it is time to clean the filter. Select the time setting
for the filter sign display interval in the table below according to the amount of dust or debris in the
room. If you do not wish the filter sign to be displayed, select the setting value for "No indication".
Setting Description
"Standard
(2,500 hours)"
"Long interval
(4,400 hours)"
"Short interval
(1,250 hours)"
No indication
1-2. Setting the ceiling height
Select the setting values in the table below according to the height of the ceiling.
Setting Description
Standard
(2.5m to 3.0m)
High ceiling
(3.0m or more)
1-3. Setting the Cooler Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be selected as shown in the table below.
Setting Description
Standard
Lower control
1-4. Setting the Heater Room Temperature Correction
Depending on the installed environment, the room temperature sensor may require a correction.
The settings may be changed as shown in the table below.
Setting Description
Standard
Lower control
Slightly warmer control
Warmer control
Filter sign
Ceiling height
Auto restart
(  . . .Factory setting)
Function Number
Setting Value
11
(  . . .Factory setting)
Function Number
Setting Value
20
(  . . .Factory setting)
Function Number
Setting Value
30
(  . . .Factory setting)
Function Number
Setting Value
31
- (01 - 25) -
00
01
02
03
00
01
00
01
00
01
02
03