Start-up
6.5

Measurement mode

After having applied power, the following will be displayed on the LCD display:
Fig. 12: Indication in the measurement mode
In the measurement mode the current measurement value and the switching thresholds will be
shown.
Axxxx
Digitalized absolute measurement value sensor (0-1024)
Lxxx
Lower absolute threshold (0-999)
Uxxx
Upper absolute threshold (0-999)
Since the display shows the actual measurement value as well as the set switching thresholds, it
can easily be checked whether the thresholds are correctly set.
2-sheet threshold:
The threshold for 2-sheet should be selected such that it is located slightly above the normal
variation range for 1-sheet, but will be significantly exceeded in case of 2-sheet so that 2-sheet will
be securely detected.
0-sheet threshold:
The threshold for 0-sheet should be selected such that it is located slightly below the normal
variation range for 1-sheet, but will be significantly exceeded in case of 0-sheet so that 0-sheet will
be securely detected.
Pos: 35 /Doppelblech/Geräte/R100/6 Inbetriebnahme / Bedienung/Teach-In @ 0\mod_1184849560375_501.doc @ 4135
26
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Manual
Double Sheet Detector R100-Serie A100
for single sided sensors
100Teach-In.bmp
B0003306 / Rev. 1.0