Honeywell Esser 2 Series Operation And Installation Instruction page 61

Extinguishing control computer
Table of Contents

Advertisement

Available languages

Available languages

11
General ..................................................................................................................................................................... 62
12
Display and control panel ........................................................................................................................................ 63
12.1
Single Zone display....................................................................................................................................... 64
12.1.1
Status display of the zones.................................................................................................. 64
12.1.2
Status display of the outputs................................................................................................ 65
12.2
Operating displays......................................................................................................................................... 66
12.3
Trouble displays ............................................................................................................................................ 68
12.4
Keypad functions........................................................................................................................................... 70
12.5
Connect / disconnect zones ......................................................................................................................... 71
12.6
Connect / disconnect relay outputs.............................................................................................................. 72
12.7
Test mode...................................................................................................................................................... 73
12.8
Revision mode............................................................................................................................................... 74
12.9
Resetting the panel 8010.............................................................................................................................. 75
12.10
Lamp test ....................................................................................................................................................... 75
13
Control indicator and Alarm counter (Option)......................................................................................................... 76
14
Installation Instruction............................................................................................................................................... 77
Designs
Series 2
(Part No. 788010 / 788011)
Series 3
(Part No. 788012 / 788013)
19 inch Series 2
(Part No. 788024 / 788025)
19 inch Series 3
(Part No. 788014 / 788015)
Environmental conditions category: A
Response time for activation status: maximum 3 seconds
Response time for activation of outputs: maximum 1 second
The facility can be equipped in various configuration levels (in terms of number, system type and extinguishing
range options).
Number of extinguishing ranges:
System type for the extinguishing range:
Available options with requirements:
-
Activation signal delay (Sect. 4.17); range 0 s to 60 s
-
Signal that represents the flow of the extinguishing agent (Sect.. 4.18)
-
Monitoring of the status / position of components (Sect. 4.19)
-
Stop button (Sect. 4.20)
-
Control of flooding times (Sect. 4.21); range 4 s to 600s
-
Initiation of subsequent flooding (Sect. 4.22)
-
Activation signals to devices within the fire extinguishing system (Sect. 4.24)
-
Trigger signal to spare bottles (Sect. 4.25)
-
Activation signals to devices outside the fire extinguishing system (Sect. 4.26)
FB 798352 / 11.07
0786
Novar GmbH, Dieselstrasse 2, D-41469 Neuss
0786 - CPD - 20223
1
High or low gas pressure, for use with the following extinguishing gases:
argon, CO
, FM200 (HCF-227EA), Inergen, Novec KD 1230, nitrogen, Trigon