SYSTEM DESCRIPTION, INSTALLATION, AND MAINTENANCE MANUAL
authentication. It assists in the replacement of faulty SDUs as it minimizes SDU
configuration steps.
(2)
The USIM and Security Smart Card application reside on UICCs (Universal Integrated
Circuit Card). Inmarsat has developed the applications and specifies the permissible
devices which have the application loaded on them.
(3)
The SCM has no Complex Electronic devices. The software can only be loaded in the
factory.
B.

SCM System Characteristics

(1)
Table 1-4 provides the specifications for ASPIRE 400 HPA, SDU and SCM
Component
SCM
5.

Inmarsat Variations (TASK 23-15-49)

A.

Scope

(1)
Please note all processes described in this plan apply to the development of both
classes.
(2)
This plan includes schedule information for each of the applications.
(3)
These classes are detailed in the Table 1-5 Equipment Class and Subclass Identification:
EFFECTIVITY
ALL
© Honeywell International Inc. Do not copy without express permission of Honeywell.
ASPIRE-400
Table 1-4. SCM Component Specifications
Characteristic
Part Number
Length
Width
Height
Weight
Power Dissipation
Power Consumption
Operating Voltage
Cooling
Maintenance
Interfaces
System Requirements
Specification
90402652-000
4.75 Inches (120.7 mm) MAX
1.00 Inches (25.4 mm) MAX
4.00 Inches (101.6 mm) MAX
0.50 Lbs (0.23 Kg) MAX
10.7 W MAX
16 W MAX
18 VDC MAX
PASSIVELY COOLED AND DOES NOT REQUIRE
FORCED AIR. THERE ARE NO INTERNAL
COOLING FANS.
No scheduled maintenance Required
15 Position D-SUB Plug MALE (TE 5745908-2)
RTCA/DO-160G
23-15-49
3rd rvw Draft as of:
29 January, 2020
Page 1-11