Error Diagnostics

The information in the following section offers support to help you locate and
perhaps correct common errors by yourself.
Error/Cause
POWER LED does not light
MPI cable not connected
Automation system is switched off
Hardware error
USB LED does not light
USB cable not connected
PC and PC Adapter USB are in energy saving
mode (hibernate mode).
PC Adapter USB is not detected by the PC
MPI LED does not light
MPI cable not connected
Firmware not loaded
No LED lights
MPI cable not connected
The required 24 V are not available at the MPI
socket
Hardware error
POWER LED flashes continuously
Hardware error
PC Adapter USB
A5E00166354-02
13.05.2003
13.05.2003
3.05.2003
13.05.2003
Remedy
Connect MPI cable
Switch on automation system
Inform Customer Support
Connect USB cable
Enter a reliable operating mode
Check driver installation and reinstall if
necessary
Connect MPI cable
Start the supplied firmware update
utility and check if the firmware is
loaded.
Connect MPI cable
Check cabling
Inform Customer Support
If the POWER LED of the device
continues to flash continuously even
after pulling and plugging the MPI
cable several times, the device is
defective and should be exchanged.