How to assemble your Overhead Storage
Tools Required
Power Driver
Drill Bit
Level
Tape Measure
Step 1
1.1 Position Wall Cleat onto wall.
1.2 Measure distance (67.754 for 19" high , 79.765 for 31" high cabinets)
from Floor to center of bottom holes in wall cleat.
1.3 Measure 2" in from where case is to be located to find the vertical
position of wall cleat. Mark Location.
2"
67.765 (19")
79.567 (31")
HermanMiller for Healthcare
Stud Finder
Phillips Bit
Laser Level &
Tripod
Pencil
Safety Glass
Wall Cleat
Cabinet
Floor
Parts Included
Overhead Storage
Glovebox/Paper Towel
Additional Product Needed - Sold Seperately
CH105. Toggle Bolts
(CH300., CH310. Wall Mounted Cases)
Note: Field supplied #10-3/16" Flat Washer.
Note: Please refer to Mora System planning guide for different wall
constructions.
Step 2
2.1 Set up self-leveling laser to match mark, on wall.
2.2 Align Wall Cleat to level line and distance from outside cabinets. Using
Cleat as template, mark mounting holes.
1BJM4F rev D
1
Sloped Top Overhead
Overhead Storage
Storage
CH110. Ganging Hardware
CH100 Wall Cleat
Mark Holes
Assembly Instructions

Advertisement

loading
Need help?

Need help?

Do you have a question about the Mora System Overhead Storage and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for HermanMiller Mora System Overhead Storage

  • Page 1 1.3 Measure 2” in from where case is to be located to find the vertical position of wall cleat. Mark Location. 2” Wall Cleat Cabinet Mark Holes 67.765 (19”) 79.567 (31”) Floor 1BJM4F rev D HermanMiller for Healthcare Assembly Instructions...
  • Page 2 4.2 Arrange cases in proper location in run. 4.1 Mount cabinet onto wall cleat. Mate cabinet cleat with wall cleat. 4.3 Make sure cases mate tight together. Wall Cleat Cabinet Cleat Cabinet 1BJM4F rev D HermanMiller for Healthcare Assembly Instructions...
  • Page 3 Counter-clockwise to move door away from hinged side. Turn counter- door down, turn cam screw clockwise on left hinge. Adjust both hinges on clockwise for opposite door movement. each door as necessary until proper door height is set. 1BJM4F rev D HermanMiller for Healthcare Assembly Instructions...