1-3. Operating Conditions

1-4. Power Supply

1-3. Operating Conditions
c
Good air circulation is essential to prevent internal heat
build-up. Place the unit in location with sufficient air
circulation.
Do not block the ventilation holes of the cabinet and the
front and rear panels.
Operating temperature:5dC to 40dC
Operating humidity:
25% to 80% (non-condensing)
Storage temperature: _20dC to 60dC
Locations to avoid:
. Areas where the unit will be exposed to direct sunlight
of any other strong lights.
. Areas near heat sources.
. Dusty areas or areas subject to vibration.
. Areas with strong magnetic field.
. Areas with much electrical noise.
. Areas with much static electricity.
. Areas that is impossible to find a specified room for
installation. (Refer to "1-5. Installation Space".)
. Areas windtight.
Tilt allowance:
Within 30d (Do not slant the front
and rear of the unit more than 30d.)
c
Fix the unit securely to avoid drop when the unit is operat-
ed at not-horizontal place.
1-4. Power Supply

1-4-1. Voltage and Power Requirements

This unit's power line has a switching regulator.
c
Be sure to operate the unit within the range of following
power voltage.
AC 100 to 240 V ± 10%
Power voltage:
Power frequency:
50 Hz or 60 Hz
Power consumption:
190 VA
Rush current:
Power voltage 100 V IN; 10 A
Power voltage 240 V IN; 20 A
n
AC power supply is required a capacity which is commen-
surate with rush current.
If the capacity of the AC power supply is not enough, the
breaker of AC power of a supply side may operate or this
unit may not operate normally.
1-2

1-4-2. Power Cord

This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
Use the specified power cord only when connecting the
AC power.
Never use a injured power cord.
For customers in the U.S.A. and Canada:
1 Power cord 125 V 10 A (2.4 m) :
2 Plug holder (Brown) :
1
For customers in the United Kingdom:
1 Power cord 250 V 10 A (2.4 m) :
2 Plug holder (Brown) :
1
For customers in European countries except the United
Kingdom:
1 Power cord 250 V 10 A (2.4 m) :
2 Plug holder (Brown) :
1
If the unit is used in the area except above, please contact
your local Sony Sales Office/Service Center.
! 1-557-377-11
3-613-640-01
AC inlet
2
! 1-782-165-11
3-613-640-01
AC inlet
2
! 1-782-164-11
3-613-640-01
AC inlet
2
DNW-A22/A22P

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dnw-a22p

Table of Contents