Minimum height to extractor as
recommend in hood instruction
manual. If not recommended in the
hood instruction manual, this height
should be at least 650 mm.
** Minimum distance between
cabinetry must be equal to width of
hob
Hob
Burner
Control
Plate Type
Type
Side knob
Metal
control
Side knob
Glass
control
Front knob
Metal
control
/Glass
Front knob
Metal
control
/Glass
*** This size will be 60mm in models using 9-steps gas taps.
# Refer to the widht dimension in the technical table section of the user manual.

Room ventilation

All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well. The air
for combustion is taken from the room
air and the exhaust gases are emitted
directly into the room. Good ventilation
is essential for safe operation of your
appliance.
Rooms with doors and/or windows
which open directly to the outer
environment
The doors and/or windows that open
directly to the outer environment must
have a total ventilation opening of the
dimensions specified in the table below
which is based on the total gas power of
the appliance (total gas power
consumption of the appliance is shown
in the technical specification table of this
user manual). If the doors and/or
windows do not have a total ventilation
Hob Width (mm)
#
580 / 610
590 / 600 / 601 /
641 / 646
580 / 585 / 590 /
600 / 601 / 641 /
646
750 / 751
X -Minimum distance between the cut-
out and the side wall.
Y -Minimum distance between the rear
edge of the cut-out and the rear wall.
X (mm)
100 mm
100 mm
170 mm
170 mm
opening corresponding to the total gas
consumption of the appliance as
specified in the table below, then there
must definitely be an additional fixed
ventilation opening in the room to ensure
that the total minimum ventilation
requirements for the total gas
consumption of the appliance is
achieved. The fixed ventilation opening
can include openings for existing
airbricks, extraction hood ducting
opening dimension etc.
Total gas
consumption
(kW)
0-2
2-3
3-4
4-6
6-8
8-10
Y (mm)
50 mm
60 mm
50 mm ***
70 mm
min. Ventilation
2
opening (cm
)
100
120
175
300
400
500