Configuration; Parameters; Expert-Charger Parameters - Bosch BAT 490 Original Instructions Manual

Charger for 12 volt and 24 volt batteries
Hide thumbs Also See for BAT 490:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
5.

Configuration

i
The configuration menu can only be accessed if the-
re is no battery connected to the BAT 490.
1. Switch on the BAT 490 (Fig. 2, Pos. 1).
 The red LED must light (Fig. 1, Pos. 3).
2. Disconnect the charging clips from the battery.
3. Press
.
 "
No battery connected
i
The BAT 490 switches the LCD off again after one
minute if
is not pressed.
4. Press
.
 The configuration menu is displayed.
Configuration
Parameter
Language
Contrast
Software version
Factory setting
5. Select menu item with
6. Press
.
 The menu item selected is opened.
i
terminates the configuration menu.
5.1

Parameters

The "Parameters" menu can be used to enter customer-
specific parameters for 12 V and 24 V batteries for "Ex-
pert charging", "Buffer mode" and "Backup" mode.
1. Select the "Parameters" configuration menu.
2. Press
.
 The "Parameters" configuration menu is displayed.
Expert charging
Expert charging
Buffer mode 13,5V 90A
Buffer mode 27,0V 45A
Backup mode 12,0V 10A
Backup mode 24,0V 10A
3. Select parameter set with
4. Press
.
 The parameter set is displayed.
Robert Bosch GmbH
" appears on the LCD.
or
.
12V
24V
or
.
Configuration | BA� 4�� | 2�
5.1.1

Expert-charger parameters

!
Incorrect parameter values (excessively high valu-
es for I or U1 and an insufficient value for "o") may
destroy the battery.
The following parameters can be selected:
Battery
I
U1
Current
Voltage
12 V
3 A – 90 A
14 V – 15.6 V 0.2 A – 5 A
24 V
3 A – 45 A
28 V – 31.2 V 0.2 A – 5 A
The "Expert charging" parameter set displays the fol-
lowing e. g.
I
U1
o
30A
14,2V
1,5A 13,4V
60A
14,2V
3,0A 13,4V
30A
14,7V
1,8A 13,7V
60A
14,7V
3,6A 13,7V
Expert charging
12V parameter change
1. Select parameter set with
2. Press
.
 The parameter appears (I current).
3. Select the parameter with
4. Press
.
 The next parameter is displayed.
5. Consecutively select all parameters.
6. Keep pressing
until the configuration menu is ter-
minated.
7. Connect the battery and select "Expert-charger"
mode.
"
The battery is charged with the set parameters.
BA� 4�� | 2�
| 2�
en
o Switching
U2
current
Voltage
12.8 V – 14 V
25.6 V – 28 V
U2
or
.
or
.
|
1 689 989 068
2012-10-30

Hide quick links:

Advertisement

Table of Contents
loading