Bosch BAT 490 Original Instructions Manual page 21

Charger for 12 volt and 24 volt batteries
Hide thumbs Also See for BAT 490:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 15
In the "Expert-charger" menu, 12 V and 24 V batteries
are charged on the basis of certain parameters. For the
two types of battery there are four parameter sets each
which can be configured in the "Parameters" menu
(refer to Section 5.1).
1. Connect the red charging clip to the positive post (+)
of the battery.
2. Connect the black charging clip to the negative
post (‒) of the battery.
3. Switch on the BAT 490 by way of the on/off switch
(Fig. 2, Pos. 1).
 The red LED (Fig. 1, Pos. 3) lights.
4. Press
.
 The battery voltage is displayed for three seconds
and the "Modes" menu then appears.
i
The BAT 490 modes are only displayed if a battery is
connected.
Mode
Standard charging
Expert charging
Buffer mode
Backup mode
Robert Bosch GmbH
Operation | BA� 4�� | 21
5. Select "Expert charging" mode with
6. Press
.
1
I
U1
30A
14,2V
60A
14,2V
2
30A
14,7V
60A
14,7V
24V charging
3
Expert charging 12V
4
Fig. 7:
Expert charging parameters
1 Parameters (refer to charging characteristic Fig. 6)
2 12 V parameter sets
3 Call-up of 24 V parameter sets
4 Display of mode selected (12 V or 24 V)
7. Select parameter characteristic with
8. Press
.
 The green LED flashes (Fig. 1, Pos. 4).
 The battery is charged.
I
U1
1
23Ah charged
2
13,47V
65,0A
3
Expert charging
4
60A
14,4V
Fig. 8:
Expert charging
1 Charging progress (refer to charging characteristic Fig. 6)
2 Charging current supplied so far
3 Current battery charge
4 Information on mode and parameter set selected
i
For exhausted batteries, the BAT 490 initially em-
ploys soft charging. The charging current level is
governed by parameter I (15 % of I). The message
"
Soft charge
" appears on the display and the
green and yellow LEDs flash at 1-second intervals.
9. Charging is stopped with
charging clips.
 The yellow LED is off.
 The menu "Modes" is displayed (only with batte-
ry connected).
i
If charging is interrupted, the process must be
re-started.
10. Switch off the BAT 490 on completion of charging.
11. Remove the charging clips from the battery.
BA� 4�� | 21
| 21
or
.
o
U2
1,5A 13,4V
3,0A 13,4V
1,8A 13,7V
3,6A 13,7V
or
.
o
U2
3,0A
13,4V
or by disconnecting the
|
1 689 989 068
2012-10-30
en

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents