General Data - LG ARND DCR4 Series Installation Manual

Split compact dedicated outdoor air system (doas)
Hide thumbs Also See for ARND DCR4 Series:
Table of Contents

Advertisement

GENERAL DATA

Table 1: Split Compact DOAS General Data.
Unit Model No.
Cooling Mode Performance
Total Cooling Capacity (Btu/h)
Hot Gas Reheat Capacity (Btu/h)
Moisture Removal Capacity (lb. / h)
Heating Mode Performance
Capacity (Btu/h) (Main Coil)
Entering Air
Cooling Maximum (°F, D.B. / W.B.)
Heating Minimum (°F, D.B.)
Unit Data
Refrigerant Type
1
Refrigerant Control
Sound Power dB(A)
2
Net Unit Weight (lbs.)
Shipping Weight (lbs.)
Communication Cable
(No. x AWG)
3
Fan
Type
Motor (HP / W)
Motor / Drive
Airflow Rate (CFM)
External Static Pressure (in. w.g.)
Airflow Range (CFM)
Piping
Liquid Connection Size (in., O.D.)
High Pressure Vapor Connection Size (in., O.D.)
Low Pressure Vapor Connection Size (in., O.D.)
Condensate Drain OD (in.)
Filter
Outdoor
EEV - Electronic Expansion Valve
ECM - Electronically Commutated Motor
codes.
This data is rated 0 ft. above sea level, with 25 ft. of refrigerant piping per coil.
Main Coil Cooling Capacity Rating obtained with entering air of 95°F D.B. / 75°F W.B. and
leaving air of 52.9°F D.B. / 52.5°F W.B.
Main Coil Heating Capacity Rating obtained with entering air of 44°F D.B. and leaving air
of 70°F D.B.
Reheat Coil Heating Capacity Rating obtained with entering air of 54°F D.B. and leaving
air of 75°F D.B.
Actual discharge air temperatures may vary from discharge air temperature set-point due to changes in outdoor air processing loads.
10
ARND153DCR4
1,000 – 1,500
2" Merv 8 (25" x 20")
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
120,000
24,000
37.2
51,000
122 / 78
14
R410A
EEV
74
364
420
4 x 18
3D Plug
1 / 750
ECM / Direct
1,500
2.0
1/2 Brazed
3/4 Brazed
1-1/8 Brazed
1
Take appropriate actions at the end of HVAC equipment life to recover, recycle, reclaim or
1
destroy R410A refrigerant according to applicable regulations (40 CFR Part 82, Subpart F)
under section 608 of CAA.
Sound power levels are tested under AHRI 260 Standard.
2
3
Communication cable from the outdoor unit to the DOAS unit to be minimum 18 AWG,
4-conductor, twisted, stranded, shielded and must comply with applicable local and nation-
al codes. Ensure the communication cable is properly grounded at the outdoor unit only.
Do not ground the outdoor unit - DOAS communication cable at any other point.
Power Supply (V/Hz/Ø): 208-230/60/1
ARND203DCR4
143,100
30,000
51.5
59,900
122 / 78
14
R410A
EEV
72
364
420
4 x 18
3D Plug
1 / 750
ECM / Direct
2,000
1.5
1,000 – 2,000
1/2 Brazed
7/8 Brazed
1-1/8 Brazed
1
2" Merv 8 (25" x 20")