* Location of the network and electrical connections
The height of the room should be at least 2500 mm (99 in).
The build unit measures 652 × 760 × 1050 mm.
Environmental specifications
Temperature during installation
Operating temperature
Recommended operating temperature for best performance
Storage and reshipping temperature
Operating humidity
Storage humidity
Maximum altitude when printing
Notes
●
The customer must ensure that the room in which the system is installed meets environmental, ventilation,
and air conditioning specifications. The operating conditions (temperature and humidity) should remain as
stable as possible within the specified limits.
To ensure that environmental conditions are always met, a measuring system should be implemented. A
room-temperature and relative-humidity sensor with data logger should be used to take measurements
during installation and first builds.
The printer, build unit, and processing station should be kept at operating conditions if they contain
●
material.
The printer, build unit, and processing station should be kept indoors.
●
ENWW
20–30°C (68–86°F)
20–30°C (68–86°F)
20–30°C (68–86°F)
−25 to +55°C (−13 to +131°F)
30–70% without condensation
< 90% without condensation
3,000 m or 9,842.6 ft. (2,000 m or 6,561.8 ft. for China)
Environmental specifications
11