Installation
December 2020
2.6.1
Wire the detector
NOTICE
Wiring codes and regulations may vary. Wiring must comply with all applicable regulations
relating to the installation of electrical equipment in a hazardous area and is the installer's
responsibility. If in doubt, consult a qualified official before wiring the system.
In applications where wiring is installed in a conduit, do not use the conduit for wiring to
other equipment.
For full EMC requirements, ensure incoming cables are threaded through the ferrite beads
(provided with the detector). See
Figure 2-8: Ferrite Bead Locations
A. Thread cable through ferrite
B. Ferrite
20
Figure
2-8.
Reference Manual
00809-0100-3003
GDU-Incus