Seco SBC-C90 User Manual page 53

3.5" sbc with amd ryzen embedded r1000/v1000 family of socs
Table of Contents

Advertisement

Speed Change Duration
4.3.17.5 Watchdog Configuration submenu
Menu Item
Watchdog
Event action
Reset action
Watchdog delay
Event time-out
Reset time-out
4.3.17.6 GPIO Configurations submenu
Menu Item
GPIOx
4.3.18 HSUART Transceiver Configuration submenu
Menu Item
HSUART #0
HSUART #1
Rx Termination
SBC-C90
SBC-C90 User Manual - Rev. First Edition: 1.0 - Last Edition: 1.0 - Author: A.R. - Reviewed by C.M. Copyright © 2021 SECO S.p.A.
Default FAN Duty Cycle (%).
0 .. 50
Duration in seconds of linear FAN Speed Change.
Options
Description
Disabled / Enabled
Enables or disables the Watchdog Timer mechanism. When enabled, the following parameters will appear.
Raise WDT Signals
Select the Watchdog action when Event time-out expires
Power Button Pulse
System Reset
Power Button Override
Select the Watchdog action when Reset time-out expires
Raise WDT Signal
Minutes before watchdog normal operations starts. During delay time-out, a refresh operation will
[0..60]
immediately trigger normal operation. Valid range is from 0 to 60.
Minutes without refresh before triggering selected event action. Refresh will restart the time-out. Valid range
[0..60]
is from 0 to 60
Minutes without refresh before triggering selected reset action, this timer will start when event time-out is
[1..60]
expired. Refresh will restart the time-out. Valid range is from 1 to 60
Options
Description
Input
Output Low
Configure GPIOx pin as input or output with a fixed starting value. Last means no changes with respect to
Output High
the last boot.
Output Last
Options
Description
RS-232
RS-422
Select among RS-232 (default), RS-422 or RS-485 interface for HSUART port 0 and 1.
RS-485
Disabled / Enabled
Option available when selecting RS-422 or RS-485 mode.
53