Adjusting Hd-Sdi Amplitude - Sony HXCU-FB80 Service Manual

4k/hd camera control unit
Hide thumbs Also See for HXCU-FB80:
Table of Contents

Advertisement

4-4-3.

Adjusting HD-SDI Amplitude

Procedure
1.
Input the SLOT 2 SDI-1 or SLOT 2 SDI-2 signal to the waveform monitor that accepts HD-SDI input signals.
2.
Open MULTI FORMAT (S03) from the SYSTEM OPERATION menu.
3.
Set the item [CAMERA FORMAT] to "1080/50P" or "1080/59.94P."
4.
Open ANALOG ADJUST (M05) from the MAINTENANCE menu.
• Adjusting SLOT2 SDI-1
(1) Set [SDI2-1 1.5G] to ON.
The HD-SDI signal is output.
(2) While monitoring the waveform monitor, adjust the [SDI2-1 1.5G] value so that the amplitude meets
the specified value (800 ±80 mV).
• Adjusting SLOT2 SDI-2
(1) Set [SDI2-2 1.5G] to ON.
The HD-SDI signal is output.
(2) While monitoring the waveform monitor, adjust the [SDI2-2 1.5G] value so that the amplitude meets
the specified value (800 ±80 mV).
5.
Set to cursor at [STORE] and press the CONTROL knob.
6.
When "Write OK?" appears, press the CONTROL knob.
The adjustment values are stored.
HXCU-FB80
4-7

Hide quick links:

Advertisement

Table of Contents
loading