Parts List - Honeywell F115A1064 Product Data

Ceiling surface mounted media air cleaners

Advertisement

1. Grasp the edge of the air cleaner cover near the ple-
num and remove the cover from the support brack-
ets. Set it aside.
2. Remove the prefilters.
3. Check the prefilters and replace them if they are fully
coated with dust and lint (approximately every 1 to 3
months).
4. Replace the CPZ™ cartridge when a continuous
noticeable odor is emitted from the air cleaner
(approximately every 4 to 12 months).
5. Replace the primary filter when there is a noticeable
loss of air volume circulation (approximately every
10 to 24 months).
6. Reassemble the air cleaner and turn the power on.

PARTS LIST

Refer to Table 2 and Fig. 4 for a parts list and an exploded
view of the parts.
Table 2. F115 Ceiling Surface Mounted Media Air
Cleaner Parts List.
Fig.
Reference
No.
Description
1
Blower Wheel
2
120V, 60 Hz,
Single-Speed
Motor
3
Mid-plate
4
Prefilter (1 box)
4
Prefilter (1 Case)
5
HEPA filter
(requires 4)
5
D.O.P. Particle
filter (MERV 16)
(requires 4)
6
Disposable CPZ
canister (requires
4)
7
Filter holding
plate with stud
and nut
8
Lid/cover
5
MOUNTED MEDIA AIR CLEANERS
Pack
Qty
Order Number
4
32000229-001
40
32000230-002
1
32000206-001
1
32000217-001
1
32000232-002
68-0201—05