AVIRE Memco Panachrome+ Installation Manual

2d/3d 10mm profile
Hide thumbs Also See for Memco Panachrome+:

Advertisement

Memco Panachrome
2D/3D 10mm Profile
Installation Guide
Ref No. G510 850GB Version 2

1. Detector Installation

The Panachrome
+
10mm 3D/2D detectors can be fitted to centre-opening or side-opening doors. For the visual indicators
to be effective, the system can be installed in dynamic mode, where at least one of the detectors is fixed to a moving
door or in static mode. TX detector must be fitted to left side of lift when viewed from landing.

Installation Notes - 2D/3D

1.
Check that the door itself is grounded to the lift
2.
Use a P-clip either side of the pluggable connectors, to
reduce the risk of plug and socket separating
3.
Do not shorten Memco cables by cutting them.
4.
Position the detectors on the doors approximately 3mm
above the door sill
5.
Mark or spot through the 3 fixing holes. See Fig 1.
6.
Remove the detectors from the door before drilling

Installation Notes - 3D

When installing a Panachrome
precautions must be observed for trouble-free operation:
1.
Always mount the detectors as close to the door edge
as possible.
2.
Sight-Guards cannot be used with Panachrome
detectors.
3.
For opening exceeding 1200mm, it is recommended
that 'On at closing' mode is used.
3D system, the following
+
3D
+
7.
Drill the 3 fixing holes in the door using a 3mm drill
8.
Screw the detector to the door using the No.6 self-
tapping counter sunk screws provided
9.
Finally, check that the detectors are aligned with each
other.
4.
The detectors must be set no more than 10mm apart
when the doors are fully closed. The detectors must be
aligned to within ±8mm of the detector centre line.
5.
3D mode settings are set using the Controller menu
under 3D.
+

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Memco Panachrome+ and is the answer not in the manual?

Questions and answers

Summary of Contents for AVIRE Memco Panachrome+

  • Page 1 Memco Panachrome 2D/3D 10mm Profile Installation Guide Ref No. G510 850GB Version 2 1. Detector Installation The Panachrome 10mm 3D/2D detectors can be fitted to centre-opening or side-opening doors. For the visual indicators to be effective, the system can be installed in dynamic mode, where at least one of the detectors is fixed to a moving door or in static mode.
  • Page 2 CABLE 1000mm PANACHROME DETECTOR 100mm 3mm from sill Fig. 2: Installing the Detectors Avire Ltd Unit 1, The Switchback 01628 540100 Gardner Road 01628 621 947 Maidenhead sales.uk@avire-global.com Memco is a brand of Avire Berkshire www.memco-global.com SL6 7RJ, UK www.avire-global.com...

Table of Contents