INSTALL THE DRIP PAN ................APPLY POWER .................... 3. OPERATION THERMOSTAT SET POINTS AND HEATING COOLING UNITS ....MAINTENANCE ................... 4. APPENDIX ......................EIC SOLUTIONS INC. 700 VETERANS WAY, SUITE 200 WARMINSTER, PA 18974 PHONE 1-215-443-5190 or 1-800-497-4524 FAX 215-443-9564 EMAIL info@eicsolutions.com VISIT US ON THE WEB AT www.eicsolutions.com.
Your EIC Solutions Thermoelectric Air Conditioner operates on this principle so there is no compressor and no expensive, ozone depleting CFC’s. EIC’s air conditioners use Thermoelectric “modules”...
Model AAC-140, DC powered, 400 Btu units are not designed to be mounted on the top of an enclosure. Doing so will allow condensate to drip in an uncontrolled manner from the air conditioner on the inside of the enclosure damaging the air conditioner and the electronics within the enclosure. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
To mount the 400 Btu unit you will need to cut an opening in your enclosure and drill mounting holes. A cut out drawing showing the cut out size and hole locations has been included in this manual (see Appendix A, B). The instructions for installing the air conditioner are printed below. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
7. Remove the two starter screws and place a nylon washer on each and reinstall. 8. Tighten all screws. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
The cold side fan always runs to circulate air within your enclosure thereby eliminating any “hot spots”. The hot side fans will only run when the air conditioner is cooling – they are “pumping” the heat from the inside of your enclosure to the outside air. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
NEVER EXPOSE THE COLD SIDE OF ANY AIR CONDITIONER (INSIDE THE ENCLOSURE) TO WATER. If you have any questions about any aspect of your EIC air conditioner, don’t hesitate to call us at the numbers listed below. -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
APPENDIX A Enclosure cutout for 400 BTU air conditioner NON-EXTENSION FRAME Holes to be 8-32 TAP -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
Page 10
APPENDIX B Enclosure cutout for 400 BTU air conditioner EXTENSION FRAME OPTION ONLY Holes to be .1875” Clearance -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
Page 11
APPENDIX C Wiring for 400 BTU Models without heat option APPENDIX D -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...
Page 12
Wiring for 400 BTU Models with heat option -800-497-4524 EIC SOLUTIONS, INC 215-443-5190...