Chapter 52 PoE PSU Supervision Configuration

52.1 Introduction to PoE PSU Supervision

The PoE-capable Switch 8800 can monitor the external PoE PSUs through the power
supervision module on the PoE external power system.
The PoE PSU supervision module enables you to:
Set the alarm thresholds for the AC input voltages of the PoE PSUs.
Set the alarm thresholds for the DC output voltages of the PoE PSUs.
Query PSU information such as voltage and power.

52.2 AC Input Alarm Thresholds Configuration

You can set the AC input alarm thresholds for the PoE PSUs to enable the Switch 8800
to monitor the AC input voltages of the PSUs in real time through the PoE supervision
module.

52.2.1 AC Input Alarm Thresholds Configuration Tasks

Table 52-1 AC input alarm thresholds configuration tasks
No
1
Enter system view
Set the overvoltage alarm
2
threshold of AC input (upper
threshold) for the PoE PSUs
Set the undervoltage alarm
3
threshold of AC input (lower
threshold) for the PoE PSUs
Display the AC input state of
4
each PoE PSU
Chapter 52 PoE PSU Supervision Configuration
Item
system-view
poe-power
upper string
poe-power
lower string
display
ac-input state
52-1
Command
Required,
input-thresh
and the max
voltage
264.0 V.
Required,
input-thresh
and the min
voltage
90.0 V.
Optional, and
you
poe-power
execute this
command in
any view.
Description
is
is