For the Fitter
Connection of supplementary heater (ZH) with existing internal room temperature regulator (RTi) . . .
RTi 100 M
Circuit diagram WSP 2010 - 7010 with ZH and RTi 100 M
E1 - E6:
Heating element (storage heater)
E7:
Heating resistor
F1:
Safety temperature limiter
M1 - M3:
Fan
N1:
Temperature limiter - charging
N5:
Temperature limiter – fan drawer
N4:
Temperature limiter - charging
X1:
Mains terminal
X2:
Terminal
bk, approx. 420 lg
bk, approx. 150 lg
AC-signal 230 V
Charging control signal
22
X
E9:
N6:
S2:
Z1:
X
E8:
N2:
N3:
S1:
X = cable harness
bl., approx. 230 lg
Control circuit
1/N/PE ~ 50 Hz 230 V
Integr. room temperature regulator RTi 101 M
Heating resistor
Temperature regulator - discharging
Rocker switch - discharging
Radio interference suppressor
Supplementary heater
Supplementary heating element
Temperature regulator – supplementary heater
Temperature regulator – supplementary heater
Rocker switch – supplementary heater
3/N/PE ~ 50 Hz 400 V